LTE FDD/TDD Signal Analyzer Measurement Guide : LTE Analyzer (Option 883) : Setting Frequency and Bandwidth Parameters
 
Setting Frequency and Bandwidth Parameters
Frequency and channel bandwidth parameters are set using the FREQ SPAN Menu. The channel center frequency and bandwidth can be set manually. When set to manual band, the EARFCN is unassigned. When a predefined EARFCN is selected, the uplink and downlink carrier frequencies are set automatically.
Configuring the Band
These settings are also displayed in the left side status panel and can be directly accessed from those controls.
1. Press FREQ SPAN > CENTER FREQUENCY, and then enter the center frequency using the keypad.
2. Select the channel bandwidth from the CHANNEL BW selection list.
3. Select the EARFCN code form the drop-down selection.
FREQ SPAN Menu
The FREQ SPAN menu is available in all LTE measurements.
FREQUENCY Menu (LTE Measurements)
-
 
CENTER FREQUENCY
Sets the center frequency of the measurement channel.
SPAN
Sets the current frequency span.
 
CHANNEL BW
Sets the measurement channel bandwidth. The available bandwidth settings depend on the selected band and bandwidth option installed in the instrument.
EARFCN
E-UTRA Absolute Radio Frequency Channel Number (EARFCN) uniquely identifies the LTE band and carrier frequency. Sets the uplink and downlink carrier frequencies, which range from 0 to 65535.
SIGNAL STANDARD
Opens the SIGNAL STANDARDS Dialog. This dialog provides a selection list of predefined LTE signal standards. Selecting an LTE signal standard configures the instrument for measurements in the selected band.
GESTURES
Opens the GESTURES Menu. Not shown in LTE Modulation measurements.
SIGNAL STANDARDS Dialog
The SIGNAL STANDARDS dialog is available in all LTE measurements.
SIGNAL STANDARDS Dialog (LTE Measurements)
-
GESTURES Menu
The GESTURES menu is only available in RF measurements (trace displays).
GESTURES Menu (LTE RF Measurements) 
-
 
DRAG
Toggles the touchscreen drag feature on or off. When toggled off, the center frequency will not change when dragging the spectrum display. This can be useful when dragging markers.
Note that the Drag feature can also be toggled on/off by touching the locks under the display.