VectorStar™ MS4640A Series Microwave Vector Network Analyzers : Power Menus - 2-Port VNAs : POWER Menu Variants - 2-Port VNAs
 
POWER Menu Variants - 2-Port VNAs
POWER Menu Name and Button Changes
The name of the POWER menu can be POWER or POWER [COUPLED] depending on the settings on the POWER SETUP menu.
POWER: On the POWER SETUP menu, the Port Power button is set to Not Coupled.
POWER [COUPLED]: On the POWER SETUP menu, the Port Power button is set to Coupled.
On POWER menus with frequency-based sweeps, the button to link to the POWER SETUP menu is labeled the Other Setup button. These sweeps are Freq Sweep (Linear), Freq Sweep (Log), Segmented Sweep (Freq-based), and Segmented Sweep (Index-based). Note that the Other Setup button is not available with segmented sweeps.
On POWER menus with power-based sweeps, the button to link to the POWER SETUP menu is labeled the Power Setup button. These sweeps are Power Sweep (CW Freq) and Power Sweep (Swept Freq).
Navigation for Frequency-Based Sweeps
MAIN | Power | POWER | Other Setup | POWER SETUP
POWER SETUP Menu - Frequency-Based Sweep - 2-Port VNAs
Navigation for Power-Based Sweeps
MAIN | Power | POWER | Power Setup | POWER SETUP
POWER SETUP Menu - Power-Based Sweep Menu - 2-Port VNAs
POWER Menu Button Changes
The POWER menu can have 13, 5, or 9 buttons depending on the SWEEP TYPE settings.
POWER Menu with Frequency-Based Sweeps
If SWEEP TYPE is set to Frequency-Based Sweep (Linear or Log):
The POWER menu has 13 buttons, one of which is the Attenuators button linking to the ATTENUATORS menu.
The POWER SETUP menu has 5 buttons, including buttons for Port Selection, Apply Slope, Slope, and Port Power.
POWER Menu with Segment-Based Sweeps
If SWEEP TYPE is set to Segment-Based Sweep (Frequency or Index):
The POWER menu has 5 buttons, one of which is the Attenuators button linking to the ATTENUATORS menu.
The POWER SETUP menu is not available. Instead, per-port power and effective power is set on a per-segment basis in the Segmented Sweep Setup Tableau dialog area.
MAIN | Sweep Setup | SWEEP SETUP | Freq-Based Seg Sweep Setup | FREQ BASE SETUP
FREQ BASE SETUP Menu
MAIN | Sweep Setup | SWEEP SETUP | Index-Based Seg Sweep Setup | INDEX BASE SETUP
INDEX BASE SETUP Menu
POWER Menu with Power-Based Sweeps
If SWEEP TYPE is set to Power-Based Sweep (CW or Swept Frequency):
The POWER menu has 9 buttons.
The Attenuators button is not present on the POWER menu, but is moved to the POWER SETUP menu.
The POWER SETUP menu has 9 buttons, including buttons for Attenuators, Power Cal, Receiver Cal, and External Source Power.
POWER Menu - Frequency-Based Sweep - 2-Port VNAs
Previous
MAIN MENU
Navigation
MAIN | Power | POWER
Prerequisites
Sweep Type = Frequency-Based Sweep (Linear or Log)
Frequency-Based Sweep (Linear) Setup
MAIN | Sweep Setup | SWEEP SETUP | Sweep Type | SWEEP TYPES | Freq Sweep (Linear)
Sweep Setup and Sweep Type Menus
Frequency-Based Sweep (Log) Setup
MAIN | Sweep Setup | SWEEP SETUP | Sweep Type | SWEEP TYPES | Freq Sweep (Log)
Sweep Setup and Sweep Type Menus
 
POWER [COUPLED] Menu - Frequency-Based Sweeps - 2-Port VNAs
Port 1 Power
Select displays the Port 1 Power field toolbar and allows setting the port 1 power level in dBm. If Port Power is set to coupled, changes to the Port 1 Power level affect the Port 2 Power level.
Effective (Port 1) Power (dBm)
Read-only display. Shows the effective Port 1 power after any applied attenuator.
Effective Pwr (>54G) (dBm)
This read-only button is only present if the instrument is an MS4647A VNA with Option 080/081 and, on the APPLICATION menu, the Modular BB is selected. The additional button is shown below.
Port 2 Power
Select displays the Port 2 Power field toolbar and allows setting the port 2 power level in dBm. If Port Power is set to coupled, changes to the Port 2 Power level affect the Port 1 Power level.
Effective (Port 2) Power (dBm)
Read-only display. Shows the effective Port 1 power after any applied attenuator.
Effective Pwr (>54G) (dBm)
This read-only button is only present if the instrument is an MS4647A VNA with Option 080/081 and, on the APPLICATION menu, the Modular BB is selected. See example above.
 
Attenuators
Button Not Present
If the Attenuators button is not present, the SWEEP TYPE is set to Power-Based Sweep (CW or Swept Frequency). The button is available on the POWER SETUP menu described in the section below. The operation on the POWER SETUP menu is the same as described here.
Button Not Available
If the Attenuators button is present but unavailable, the attenuator options have not been installed in your instrument. Contact Anritsu Customer Service for more information.
Button Available
If the Attenuators button is available, one of the attenuator options has been installed:
Option 061: Includes Port 1 Source Attenuator and Port 2 Test Attenuator.
Option 062: Includes Port 1 Source Attenuator, Port 2 Source Attenuator, Port 1 Test Attenuator, and Port 2 Test Attenuator.
Select displays the ATTENUATORS menu and allows the user to configure Source and Test attenuators for port 1 and port 2.
Power Cal
Select displays the POWER CAL menu.
Receiver Cal
Select displays the RECEIVER SETUP menu.
Other Setup (Power)
Select displays the POWER SETUP [1], POWER SETUP [2], or the POWER SETUP [C] menu. The name of the POWER SETUP menu depends on the settings of the Power Selection button and the Port Power button.
External Source Power
Select displays the EXT SRC POWER (EXTERNAL SOURCE POWER) menu.
 
 
POWER Menu - Segment-Based Sweeps - 2-Port VNAs
Previous
MAIN MENU
Navigation
MAIN | Power | POWER
Prerequisites
Sweep Type = Frequency-Based Segmented Sweep or Index-Based Segmented Sweep
Segmented Sweep Frequency-Based Setup
MAIN | Sweep Setup | SWEEP SETUP | Sweep Type | SWEEP TYPES | Segmented Sweep (Freq-Based)
Sweep Setup and Sweep Type Menus
Sweep Type - Segmented Sweep Index-Based Setup
MAIN | Sweep Setup | SWEEP SETUP | Sweep Type | SWEEP TYPES | Segmented Sweep (Index-Based)
Sweep Setup and Sweep Type Menus
 
POWER [COUPLED] Menu - Segment-Based Sweep - 2-Port VNAs
Segmented Sweep Power Control Functions
Controls for power configuration is moved to the frequency- or index-based segmented sweep setup functions on the SWEEP SETUP menu. There, the following parameters for each created segment can be defined:
Basic controls add, delete, clear, save, and recall segments
Configuration controls for graph mode and ON/OFF display of IFBW, power, and averaging
Individual segment controls for:
Segment ON/OFF
Segment definition as either Start and Stop, Start and Step-Size, or CW
Number of points per segment
Calculated Step Size
IF Bandwidth (IFBW)
Port 1 Source Power
Port 2 Source Power
Averaging number of points
Navigation:
MAIN | Sweep Setup | SWEEP SETUP | Freq-Based Seg. Sweep Setup | FREQ BASE SETUP
MAIN | Sweep Setup | SWEEP SETUP | Freq-Based Seg. Sweep Setup | FREQ BASE SETUP
 
Attenuators
Button Not Available
If the Attenuators button is present but unavailable, the attenuator options have not been installed in your instrument. Contact Anritsu Customer Service for more information.
Button Available
If the Attenuators button is available, one of the attenuator options has been installed:
Option 061: Includes Port 1 Source Attenuator and Port 2 Test Attenuator.
Option 062: Includes Port 1 Source Attenuator, Port 2 Source Attenuator, Port 1 Test Attenuator, and Port 2 Test Attenuator.
Select displays the ATTENUATORS menu and allows the user to configure Source and Test attenuators for port 1 and port 2.
Power Cal
Select displays the POWER CAL menu.
Receiver Cal
Select displays the RECEIVER SETUP menu.
Other Setup (Power)
Select displays the POWER SETUP [1], POWER SETUP [2], or the POWER SETUP [C] menu. The name of the POWER SETUP menu depends on the settings of the Power Selection button and the Port Power button.
External Source Power
Select displays the EXT SRC POWER (EXTERNAL SOURCE POWER) menu.
 
POWER Menu - Power-Based Sweeps - 2-Port VNAs
Previous
MAIN MENU
Navigation
MAIN | Power | POWER
Prerequisites
Sweep Type = Power-Based Sweep (CW Frequency or Swept Frequency)
Power-Based Sweep (CW Frequency) Setup
MAIN | Sweep Setup | SWEEP SETUP | Sweep Types | SWEEP TYPES | Power Sweep (CW Freq)
Sweep Setup and Sweep Type Menus
Power-Based Sweep (Swept Frequency) Setup
MAIN | Sweep Setup | SWEEP SETUP | Sweep Types | SWEEP TYPES | Power Sweep (Swept Freq)
Sweep Setup and Sweep Type Menus
 
POWER [COUPLED] Menu - Power-Based Sweep - 2-Port VNAs
Power Points
Select displays the Power Points field toolbar and allows selection of the total number of power points in the sweep.
Power Points
Select displays the Power Points field toolbar and allows selection of the total number of power points in the sweep.
Port Selection
The Port Selection button displays the SELECT PORT dialog box which allows touch screen selection of Port 1 or Port 2. The selected port is shown in the button display field.
 
Start (Power) (dBm)
For the displayed port above, select displays the Start (dBm) field toolbar where the start power level is set.
Effective Start (Power) (dBm)
A read only display that shows the effective start power after the application of any attenuator effects.Stop (Power) (dBm)
Eff. Start (>54G) (dBm)
Effective Start Power >54 GHz Port 1. This read-only button is only present if the instrument is an MS4647A VNA with Option 080/081 and, on the APPLICATION menu, the Modular BB is selected. The additional button is shown below.
Stop (Power) (dBm)
For the displayed port, select displays the Stop (dBm) field toolbar where the stop power level is set.
Effective Stop (Power) (dBm)
A read only display that shows the effective stop power after the application of any attenuator effects.
Eff. Stop (>54G) (dBm)
Effective Stop Power >54 GHz Port 1. This read-only button is only present if the instrument is an MS4647A VNA with Option 080/081 and, on the APPLICATION menu, the Modular BB is selected. See example above.
 
Power Offset (dB)
Select displays the Power Offset (dB) field toolbar where offsets can be applied.
Step Size (dB)
The button display field calculates the step size based on the start value, stop value, and the number of power points set in the field toolbars above or allows input of a required step size value. If a new value is input, the number of power points changes as required.
Power Setup
Select displays the POWER SETUP menu which contains the controls for Attenuators, Power Cal, Receiver Cal, and External Source Power. For a frequency-based sweep, these controls are located on the POWER menu.
MAIN | Power | POWER | Other Setup | POWER SETUP