VectorStar™ MS4640A Series Microwave Vector Network Analyzers : Calibration Menus - 4-Port VNAs : Manual Trans. Freq. Resp. Cal Menus and Dialog Boxes
 
Manual Trans. Freq. Resp. Cal Menus and Dialog Boxes
Full Name
Transmission Frequency Response Calibration
Menu Name
TRANS. RESPONSE
Button Name
Transmission Freq. Response
TRANS. RESPONSE Menu - 4-Port VNAs
The exact composition of the menu depends on the settings made on the CAL SETUP, CAL METHOD, and LINE TYPE menus and on the resultant TRANSMISSION FREQUENCY REPONSE CAL SETUP dialog box. A representative menu is shown below. There is one example procedure of a TRANS. RESPONSE calibration in this chapter.
Full Name
Transmission Frequency Response Menu
Previous
MANUAL CAL Menu - 4-Port VNAs
Navigation
MAIN | Calibration | CALIBRATION | Calibrate | CALIBRATE | Manual Cal | MANUAL CAL | Transmission Freq. Response | TRANS. RESPONSE
 
TRANS. RESPONSE Menu - 4-Port VNAs - Typical example
Modify Cal Setup
Select displays the CAL SETUP menu where the Edit Cal Params button provides access to the TRANSMISSION FREQUENCY RESPONSE CAL SETUP dialog box for the selected calibration method and line type.
Example transmission frequency response calibration dialog boxes are available below:
A summary table of all transmission frequency response calibration configuration dialog boxes is available here:
 
 
Port Selected
Read-only display of the ports selected for the pending calibration.
 
Other Menu Buttons
For this example menu, the buttons below Port Selected to the Isolation (Optional) button each display calibration completion submenus. Once the calibration steps on each submenu are complete, these menu buttons are marked as completed.
Done
This button is unavailable until a successful calibration procedure has been completed. When available, it returns to the CALIBRATION menu where the Cal Status button is set to ON.
Abort Cal
This button stops the current calibration procedure and returns to the CALIBRATION menu.
 
 
 
TRANS. FREQ. RESP. CAL SETUP (SOLT/R, COAXIAL) Dialog Box
Full Name
Transmission Frequency Response Calibration Setup
Previous
TRANS. RESPONSE Menu - 4-Port VNAs
Navigation
MAIN | Calibration | CALIBRATION | Calibrate | CALIBRATE | Manual Cal | MANUAL CAL | Transmission Freq. Response | TRANS. RESPONSE | Modify Cal Setup | CAL SETUP | Edit Cal Params | TRANSMISSION FREQUENCY RESPONSE CAL SETUP (SOLT/R, COAXIAL) Dialog Box
CAL SETUP must be set to Cal Method = SOLT/SOLR and Line Type = Coaxial.
 
TRANS. FREQ. RESP. CAL SETUP (SOLT/R, COAXIAL) Dialog Box
TRANSMISSION FREQUENCY RESPONSE CALIBRATION SETUP Dialog Box
Test Port Thru Selection Boxes
Allows selection of any combination of the test port throughs for the available port pairs:
Thru 1-2
Thru 1-3
Thru 1-4
Thru 2-3
Thru 2-4
Thru 3-4
Test Port Pair Thru Info Buttons
A Thru Info button becomes available for each port pair through selected above. Select displays the THRU INFO configuration dialog box for the selected port pair. A calculator icon in the THRU INFO dialog box allows access to the AIR EQUIVALENT LENGTH CALCULATOR dialog box.
Both dialog boxes are described in the AutoCal sections above.
THRU INFO Dialog Box - 4-Port VNAs
AIR EQUIVALENT LENGTH Calculator Dialog Box
Reference Impedance
Input the reference impedance.
Input field defaulted to 50 Ohms.
Any numerical value accepted although input values <0.01 Ohms are converted to 0.01 Ohms.
OK / Cancel
Click OK to accept the changes and return to the CAL SETUP menu.
Click Cancel to abandon any changes and return to the CAL SETUP menu.
 
TRANS. FREQ. RESP. CAL SETUP (SSLT, WAVEGUIDE) Dialog Box
Full Name
Transmission Frequency Response Calibration Setup
Previous
TRANS. RESPONSE Menu - 4-Port VNAs
Navigation
MAIN | Calibration | CALIBRATION | Calibrate | CALIBRATE | Manual Cal | MANUAL CAL | Transmission Freq. Response | TRANS. RESPONSE | Modify Cal Setup | CAL SETUP | Edit Cal Params | TRANSMISSION FREQUENCY RESPONSE CAL SETUP (SOLT/R, COAXIAL) Dialog Box
CAL SETUP must be set to Cal Method = SSLT and Line Type = Waveguide.
 
TRANS. FREQ. RESP. CAL SETUP (SSLT, WAVEGUIDE) Dialog Box
TRANSMISSION FREQUENCY RESPONSE CALIBRATION SETUP
Reference Impedance
Input the reference impedance.
Input field defaulted to 50 Ohms.
Any numerical value accepted although input values <0.01 Ohms are converted to 0.01 Ohms.
Waveguide Kit Selection
Select the Waveguide Kit Type from a drop-down menu list with options of:
User-Defined1 through User-Defined32
Waveguide Info Button
Select displays the USER DEFINED WAVEGUIDE (SSST) parameters dialog box. The dialog box allows user input of waveguide calibration parameters of:
Waveguide kit label. A user-defined kit label can be input here.
Cutoff frequency (GHz)
Dielectric
Offset short 1 length (mm)
Offset short 2 length (mm)
Offset short 3 length (mm)
A calculator icon provides access to the AIR EQUIVALENT LENGTH CALCULATOR dialog box described in the AutoCal sections above.
AIR EQUIVALENT LENGTH Calculator Dialog Box
The dialog box contents depend on the selected connector, calibration method, and line type. The example in the link below shows a typical standard information dialog box.
WAVEGUIDE INFO and USER DEFINED WAVEGUIDE Dialog Boxes
OK / Cancel
Click OK to accept the changes and return to the CAL SETUP menu.
Click Cancel to abandon any changes and return to the CAL SETUP menu.
 
 
TRANS. FREQ. RESP. CAL SETUP (SSST, MICROSTRIP) Dialog Box
Full Name
Transmission Frequency Response Calibration Setup
Previous
TRANS. RESPONSE Menu - 4-Port VNAs
Navigation
MAIN | Calibration | CALIBRATION | Calibrate | CALIBRATE | Manual Cal | MANUAL CAL | Transmission Freq. Response | TRANS. RESPONSE | Modify Cal Setup | CAL SETUP | Edit Cal Params | TRANSMISSION FREQUENCY RESPONSE CAL SETUP (SSST, COAXIAL) Dialog Box
CAL SETUP must be set to Cal Method = SSST and Line Type = Microstrip.
 
TRANS .FREQ. RESP. CAL SETUP (SSST, MICROSTRIP) Dialog Box
TRANSMISSION FREQUENCY RESPONSE CALIBRATION SETUP
Reference Impedance
Input the reference impedance.
Input field defaulted to 50 Ohms.
Any numerical value accepted although input values <0.01 Ohms are converted to 0.01 Ohms.
Test Port Selection Boxes
Allows selection of any combination of Test Port 1, Test Port 2, Test Port 3, or Test Port 4 as long as one port is selected.
If a port is not selected, its buttons and controls are not available.
Test Port 1 Select Cal Component
Select from Offset Short 1, Offset Short 2, or Offset Short 3
Test Port 1 DUT Connector
Select the DUT Connector Type from a drop-down menu list with options of:
User-Defined1 through User-Defined32
Test Port 1 Connector Standard Info Button
Select displays the USER DEFINED OFFSET SHORT INFO dialog box with connector calibration coefficients for the selected connector and calibration method. The dialog box contents depend on the selected connector, calibration method, and line type. See the following links for typical examples:
WAVEGUIDE INFO and USER DEFINED WAVEGUIDE Dialog Boxes
USER DEFINED MATCH DEVICES Dialog Box - LRL/LRM
Test Port 2, Test Port 3, and Test Port 4 DUT Connector
Select the DUT Connector Type from a drop-down menu list as shown above in Test Port 1.
Test Port 2, Test Port 3, and Test Port 4 Connector Standard Info Button
Select displays the USER DEFINED SHORT INFO dialog box with connector calibration coefficients for the selected connector and calibration method as described above in Test Port 1.
OK / Cancel
Click OK to accept the changes and return to the CAL SETUP menu.
Click Cancel to abandon any changes and return to the CAL SETUP menu.
 
 
Summary of Trans. Freq. Resp. Cal Setup Dialog Boxes
The table below summarizes the fields and controls in all transmission frequency response calibration setup dialog boxes. If the dialog box is described in greater detail above, a link is provided to that description. To view each dialog box, set the CAL METHOD and LINE TYPE menus to the appropriate settings, and then select the Edit Cal Params button. All transmission frequency response dialog boxes are named “Transmission Frequency Response Cal Setup (Cal Method, Line Type)
Trans. Freq. Resp. Manual Cal Setup Dialog Box Contents - 4-Port VNAs
Cal Method
Line Type
Dialog Box Input Selections and Controls
SOLT/R
Coaxial
Select Test Port Throughs: Select any combination of port pair throughs from Thru 1-2, Thru 1-3, Thru 1-4, Thru 2-3, Thru 2-4, and/or Thru 1-3. At least one through must be selected.
Thru Info Button: For each through selected above, the Thru Info [Port Pair] button is enabled. Select the Thru Info button to display the THRU INFO dialog box.
In the Thru Info dialog box, select the Calculator icon to display the AIR EQUIVALENT LENGTH CONVERSION dialog box to change units.
Reference Impedance (Ohms)
SOLT/R
Non-Dispersive
Same controls and functions as SOLT/R Coaxial above.
SOLT/R
Waveguide
Same controls and functions as SOLT/R Coaxial with the following changes:
Waveguide Kit: Select from User-Defined1 to User-Defined32
Waveguide Info button: Displays the USER DEFINED WAVEGUIDE dialog box for the waveguide kit selected above. Define the waveguide by entering values for: Cutoff frequency (GHz), Dielectric constant
SOLT/R
Microstrip
Same controls and functions as SOLT/R Coaxial with the following changes:
Microstrip Kit: Select from 10 Mil Kit, 15 Mil Kit, 25 Mil Kit, or User-Defined1 to User-Defined32
Microstrip Info button: Displays either the MICROSTRIP INFO or the USER DEFINED MICROSTRIP dialog box for the microstrip kit selected above.
SSLT
Coaxial
Same controls and functions as SOLT/R Coaxial above.
SSLT
Non-Dispersive
Same controls and functions as SOLT/R Coaxial above.
SSLT
Waveguide
Same controls and functions as SOLT/R Coaxial with the following changes:
Waveguide Kit: Select from Wr10, WR15, WR20, and User-Defined1 to User-Defined32
Waveguide Info button: Select displays either the WAVEGUIDE INFO (SSLT) or the USER DEFINED WAVEGUIDE dialog box for the waveguide kit selected above. Define the user waveguide by entering values for: Cutoff frequency (GHz), Dielectric constant
SSLT
Microstrip
Same controls and functions as SOLT/R Coaxial with the following changes:
Microstrip Kit: 10 Mil Kit, 15 Mil Kit, 25 Mil Kit, User-Defined1 to User-Defined32
Microstrip Info button: Displays MICROSTRIP INFO dialog box for selected calibration method and kit. Typical dialog boxes on the links below.
SSST
Coaxial
Same controls and functions as SOLT/R Coaxial above.
SSST
Non-Dispersive
Same controls and functions as SOLT/R Coaxial above.
SSST
Waveguide
Same controls and functions as SOLT/R Coaxial with the following changes:
Waveguide Kit: User-Defined1 to User-Defined32
Waveguide Info button: Displays WAVEGUIDE INFO dialog box for selected calibration method and kit.
SSST
Microstrip
Same controls and functions as SOLT/R Coaxial with the following changes:
Microstrip Kit: 10 Mil Kit, 15 Mil Kit, 25 Mil Kit, User-Defined1 to User-Defined32
Microstrip Info button: Displays MICROSTRIP INFO or the USER DEFINED MICROSTRIP dialog box for selected calibration method and kit.
LRL/LRM
LRL/LRM calibration method is not available for the Transmission Frequency Response calibration type.