VectorStar™ MS4640A Series Microwave Vector Network Analyzers : File Management Menus : File Menus and Dialog Boxes
 
File Menus and Dialog Boxes
 
FILE Menu
Previous
MAIN MENU
Navigation
MAIN | File | FILE
 
FILE Menu – Data Save/Recall Functions – Print Functions
 
Recall Setup
Select displays the Recall Setup dialog box which allows recalling of previously saved setup files.
RECALL SETUP Dialog Box
Recall Data
Select displays the Recall Data dialog box.
RECALL DATA Dialog Box
Save Setup
Use the Save Setup button to save variations of the current instrument setup. The configurations that can be saved are of the following types:
Active Channel Setup and Calibration CHX files
Active Channel Setup STX files
All Channel Setup and Calibration CHA files
All Channel Setup STA files
Select displays the Save Setup dialog box.
SAVE SETUP Dialog Box
Save Data
Use the Save Data button to save the active channel data in several different formats and different purposes. For example, save data as a TXT file for use in another application such as a spreadsheet or word processor. Note the TXT data cannot be imported back into the instrument. Available formats are:
Active Channel TXT files
Active Channel S1P files
Active Channel S2P files
Active Channel M2P files
Active Channel CSV files
Active Channel BMP files
Active Channel PNG files
Active Channel JPEG files
Active Trace Data (Formatted) TDF files
Active Trace Data (Unformatted) TDU files
Select displays the Save Data dialog box.
SAVE DATA Dialog Box
Print
Select prints the current main display to the default printer using a standard Windows PRINT dialog box. Print confirmation dialogs appear as the print job is spooled to the default printer. Note that the default printer and its configuration is set from the Windows Desktop using the PRINTERS AND FAX dialog box. If the VNA is standalone and not on a network, the attached printer is used. If the VNA is networked, any network printer can be used.
Page Setup
Select displays the PAGE SETUP dialog box where the paper size, margins, paper orientation, and other printer parameters can be set.
PAGE SETUP Dialog Box
Print Setup
Select displays the PRINT SETUP dialog box where various print output parameters can be configured and set.
PRINT SETUP Dialog Box
Exit
Select displays an exit warning, and if confirmed, ends all MS4640A processes, and exits the VNA application to the Windows operating system desktop.
RECALL SETUP Dialog Box
 
Use the Recall Setup dialog to recall one of several types of previously saved setup for general instrument configuration.
Power-On Configuration Setup
Note that this dialog does not set the power-on configuration setting.
Power-on settings are configured in the POWER-ON SETUP menu located within the SYSTEM menus.
POWER-ON SETUP Menu
MAIN | System | SYSTEM | Power-On Setup | POWER-ON SETUP
Previous
FILE Menu
Navigation
MAIN | File | FILE | Recall Setup | RECALL SETUP Dialog Box
 
RECALL SETUP Dialog Box
 
Instructions
Use this dialog to select a previously stored setup configuration file.
1. Navigate to the File menu and the Power-On Setup dialog box.
MAIN | File | FILE | Recall Setup | RECALL SETUP Dialog Box
2. The Recall Setup dialog box appears.
3. Navigate to the required folder (recommend C:\AnritsuVNA folder) and locate the required setup file:
Active Channel Setup and Calibration CHX files
Active Channel Setup STX files
All Channel Setup and Calibration CHA files
All Channel Setup STA files
4. Once the appropriate file is selected, click Open.
5. The selected setup file is now available for use on the PRESET SETUP menu if the Saved Setup button is selected.
MAIN | System | SYSTEM | Preset Setup | PRESET SETUP
PRESET SETUP Menu
RECALL DATA Dialog Box
 
Previous
FILE Menu
Navigation
MAIN | File | FILE | Recall Data | RECALL DATA Dialog Box
 
RECALL DATA Dialog Box
 
Instructions
Use this dialog to select a previously stored data configuration file. If the system is on hold, recall a TBF formatted file to overwrite the active trace memory. If system is not on hold, recall a TBF or TBU formatted file to overwrite the active trace memory. Note that the Active Channel TXT file cannot be imported back into the instrument.
Procedure
1. Navigate to the required folder and locate the required data file:
Active Channel S1P files
Active Channel S2P files
Active Channel M2P files
Active Channel CSV files
Active Channel BMP files
Active Channel PNG files
Active Channel JPEG files
Active Trace Data (Formatted) TDF files
Active Trace Data (Unformatted) TDU files
2. Best practices recommend the C:\AnritsuVNA folder.
3. Once the appropriate file is selected, click Open.
4. The selected data file is applied depending on the file type.
SAVE SETUP Dialog Box
 
Previous
FILE Menu
Navigation
MAIN | File | FILE | Save Setup | SAVE SETUP Dialog Box
 
SAVE SETUP Dialog Box
 
Instructions
Use this dialog to select a previously stored setup configuration file.
1. Navigate to the required folder to save the setup file.
Best practices recommend the C:\AnritsuVNA folder.
2. Select the file type from the pull-down menu in the dialog box:
Active Channel Setup and Calibration CHX files
Active Channel Setup STX files
All Channel Setup and Calibration CHA files
All Channel Setup STA files
3. Once the appropriate file type and location is selected, click Save.
4. The selected setup file is saved and available for use on the PRESET SETUP menu if the Saved Setup button is selected.
MAIN | System | SYSTEM | Preset Setup | PRESET SETUP
PRESET SETUP Menu
SAVE DATA Dialog Box
 
Previous
FILE Menu
Navigation
MAIN | File | FILE | Save Data | SAVE DATA Dialog Box
 
SAVE DATA Dialog Box
 
Instructions
Use this dialog to save a data configuration file.
1. Navigate to the required folder.
Best practices recommend the C:\AnritsuVNA folder.
2. Select the data file type from the pull-down menu:
Active Channel TXT files
Active Channel S1P files
Active Channel S2P files
Active Channel M2P files
Active Channel CSV files
Active Channel BMP files
Active Channel PNG files
Active Channel JPEG files
Active Trace Data (Formatted) TDF files
Active Trace Data (Unformatted) TDU files
3. Once the appropriate file type is selected, click Save.
4. The selected data file is saved.
PAGE SETUP Dialog Box
 
Menu Bar
MENU BAR | File | Print
Previous
FILE Menu
Navigation
MAIN | File | FILE | Page Setup | PAGE SETUP Dialog Box
 
PRINT Dialog Boxes
p
 
Instructions
Select displays the standard Windows Print dialog box to print the current main display.
If the VNA is networked, allows printing to any compatible networked printer. If a USB printer is attached, allows printing to any compatible USB printer.
If the Graphics Header information is configured, selecting PRINT outputs the display data along with any user-defined parameters. The graphics header setup outputs data when the Remote Interface Language is set to Lightning AND the Graphics Header is set to ON.
If the header is set to OFF, no header is printed, and the standard PAGE SETUP and then the PRINT dialog are displayed.
If the Remote Interface Language is set to Native or HP8510, no header is output, regardless of the header setting and the same PAGE SETUP and PRINT dialogs are displayed
For additional information, see:
MISC. SETUP Menu
REMOTE LANG. Menu
PAGE SETUP Dialog Box
PRINT SETUP Dialog Box
 
PRINT SETUP Dialog Box
 
Menu Bar
MENU BAR | File | Print Setup
Previous
FILE Menu
Navigation
MAIN | File | FILE | Print Setup | PRINT SETUP Dialog Box
 
PRINT Dialog Boxes
p
 
The PRINT SETUP dialog box allows user configuration of various print output options described below.
Output Format
This button selection group allows three choices of print output:
Bitmap (BMP) with Page Setup information
4 Trace Graphical Display
4 Trace Tabular Listing
Header Output
The header output area provides control of which display elements are to appear on the output, and the contents of each.
Include Header
When the check box is selected, all selected header elements below are included in the output type above. When the check box is not selected, no header fields are included in the output.
Model
Typically the VNA Model Number, but it can be any alphanumeric string. It may be selected for inclusion in the output or not selected.
Device ID
Typically the identification of the DUT, but it can be any alphanumeric string. It may be selected for inclusion in the output or not selected.
Operator Name
Typically the identification of the test operator, but it can be any alphanumeric string. It may be selected for inclusion in the output or not selected.
Operator Comment
Any free form comment from the test operator as alphanumeric strings. It may be selected for inclusion in the output or not selected.
Logo Setup
This area allows the inclusion of a logo on the output report. If not selected, the logo does not appear in the output.
Select Logo Type
The output can be configured to output the Anritsu Logo or a user defined logo. If the user defined logo is selected, it must be added to the VNA system as a BMP (Bit Mapped Graphic) File to a known location on the VectorStar Solid State Drive (SSD).
To load a user defined logo, copy the logo to a known SSD location. Then select the User radio button, and then browse to the logo location.
The logo will remain until changed.
If necessary, multiple logos can be added to the system and changed as needed.