Spectrum Analyzerfor Anritsu RF and Microwave Handheld Instruments : Spectrum Analyzer : Measure Menu : EMF Menu (Option 444)
  
EMF Menu (Option 444)
Key Sequence: Shift > Measure (4) key > Power and Bandwidth > EMF Measurement
EMF Menu
 
EMF
On Off
Turns EMF Measurement On and Off. Refer to EMF (Option 444).
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Back
Returns to the Power and BW Menu.
 
Masks and C/I Menu
Key Sequence: Shift > Measure (4) key > Masks and C/I
Masks and C/I Menu
 
 
Emission Mask
Opens the Emission Mask Menu.
 
 
 
 
C/I
: Opens the C/I Menu.
 
 
 
Back
: Returns to the Measure Menu.
 
Emission Mask Menu
Key Sequence: Shift > Measure (4) key > Masks and C/I > Emission Mask
Emission Mask Menu
This submenu controls the setup and display of the emission mask. The emission mask is an upper segmented limit line. It must have more than two nodes, which mean at least two segments. The spectrum emission mask measurement includes the in-band and out-of-band emissions.
 
Emission Mask On/Off
Turns On/Off the Emission Mask graph and table display.
Note: Before turning Emission Mask on, you must have created or recalled a limit line.
Recall Limit as Emission Mask
Opens the recall menu for selecting a limit line for use as the Emission Mask.
Ref Power Peak/Channel
Press to display the Reference Power as Peak or Channel. When Channel is selected, the Reference Power value is the integral of the individual peaks within the channel.
Channel Width
Channel Width is preset within the Signal Standard. Use this button to adjust the width as desired.
Peak Markers On/Off
Turning on this feature displays a peak marker within an Emission Mask segment. For example, if the Emission Mask had seven segments then there would be seven peak markers.
Back
 
Returns to the Masks and C/I Menu.
 
C/I Menu
Key Sequence: Shift > Measure (4) key > Masks and C/I > C/I
C/I Menu
 
 
On/Off
Turns carrier to interference ratio measurements on or off.
Center Freq
Press this submenu key to set the center frequency or the offset center frequency. Use the Arrow keys or the rotary knob, then press Enter. Or use the number keypad, then press a unit key or press Enter for values in MHz. With zero offset, this key displays the title Center Freq. With an offset other than zero, this key displays the title Offset Center Freq, as shown below the full menu. Refer to Frequency Menu (Freq 1/2) with Offset Function.
Span
Press this submenu key to set the frequency span. Use the Arrow keys or the rotary knob, then press Enter. Or use the number keypad, then press a unit key or press Enter for values in MHz.
Carrier Signal Type
Press this submenu key to display the C/I Signal Type Menu.
Min Sweep Time
Press this submenu key to set the sweep time. The minimum valid sweep time is displayed on the key. (The minimum valid sweep time is dependent on other settings, such as RBW and VBW.) Use the Arrow keys or the rotary knob, then press Enter. Or use the number keypad, then press a unit key or press Enter for values in µs.
Back
Returns to the Masks and C/I Menu.
 
Offset Center Freq
Submenu key label when a frequency offset has been entered.
 
C/I Signal Type Menu
Key Sequence: Shift > Measure (4) key > Masks and C/I > C/I > Carrier Signal Type
C/I Signal Type Menu
After you select a signal type, by pressing a submenu key, the C/I Menu is automatically displayed. This is the default behavior even if you press the active key (with the red circle displayed).
 
NB FHSS
Press this submenu key to set Narrowband Frequency Hopping Spread Spectrum as the interfering signal type.
WB FHSS
Press this submenu key to set Wideband Frequency Hopping Spread Spectrum as the interfering signal type.
Broadband
Press this submenu key to set Broadband (such as CDMA or GSM) as the interfering signal type.
 
 
Back
Returns to the C/I Menu. without changing the currently‑selected signal type.
 
AM/FM Demod 1/2 Menu
Key Sequence: Shift > Measure (4) key > AM/FM Demod
SPA AM/FM Demod 1/2 Menu
On/Off
Turns AM/FM Demodulation on or off.
Demod Type
Provides submenu keys to select the type of signal to be demodulated (refer to Demod Type (AM/FM) Menu):
FM Wide Band
FM Narrow Band
AM
USB
LSB
Demod Freq
Use the keypad, the directional arrow keys, or the rotary knob to enter the center frequency of the signal to be demodulated. This frequency does not have to be within the current frequency sweep range to which the instrument is set.
Demod Time
Use the keypad, the directional arrow keys, or the rotary knob to increase or decrease the demodulation time, and press the Enter key to select. The demodulation time can be set from 100 milliseconds to 500 seconds. The instrument sweeps one time for every demodulation period. Sweeping pauses during the demodulation time.
Set Demod Freq to Current Marker Freq
Sets the demodulation frequency to the frequency of the current marker.
Volume
The current volume setting is displayed on the screen. Use the up or down arrow keys or rotary knob to change the volume, and press the Enter key to select.
More
Press this submenu key to display the AM/FM Demod 2/2 (More) Menu.
Back
Returns to the Measure Menu.
 
Demod Type (AM/FM) Menu
Key Sequence: Shift > Measure (4) key > AM/FM Demod > Demod Type
SPA AM/FM Demod Menu
Press one of these submenu keys to select an AM/FM demodulation type. The red circle indicates the active selection.
FM Wide Band
Frequency Modulation
 
 
FM Narrow Band
Frequency Modulation
 
AM
Amplitude Modulation
 
USB
 
Upper Sideband. This can also be used when demodulating CW (Morse code) signals.
 
LSB
Lower Sideband. This can also be used when demodulating CW (Morse code) signals.
 
 
 
Back
Returns to the AM/FM Demod 1/2 Menu.
Refer to AM/FM/SSB Demodulation for a description of the built‑in demodulator.
 
AM/FM Demod 2/2 (More) Menu
Key Sequence: Shift > Measure (4) key > AM/FM Demod > More
SPA AM/FM Demod 2/2 Menu
 
Squelch Power
Sets the squelch power value. Use this setting to limit noise when there is no signal to demodulate. The squelch value is the limit below which no signal is displayed.
Beat Freq Osc
Sets the beat frequency of the oscillator to exactly set the demodulation frequency of USB and LSB signals. Displayed only when USB or LSB is selected as the Demod Type. This can also be used when demodulating CW (Morse code) signals.
 
 
Back
Returns to the AM/FM Demod 1/2 Menu.
 
Generator Menu
Key Sequence: Shift > Measure (4) key > Generator
This menu is available only in spectrum analyzers with a Tracking Generator option.
SPA Generator Menu
 
 
Generator Output
On Off
Turns the Tracking Generator Option on and off.
 
For more information about the Tracking Generator, refer to the Tracking Generator Measurement Guide, Anritsu part number 10580-00339.
 
 
 
 
 
 
 
 
 
 
 
 
Back
Returns to the Measure Menu.