Backhaul Analyzer for Anritsu’s RF and Microwave Handheld Instruments : T1/FT1 Analyzer (Option 51 or 54)   : In‑service Measurements : Vpp Measurement Procedure
  
Vpp Measurement Procedure
This test measures the amplitude of the output signal from the PCM port to the DSX and receiving station. These measurements provide detailed information on the T1 circuit.
1. Press the Measurements main menu key to activate the Measurements menu.
2. Press the Rx Signal submenu key to select the Vpp measurement.
3. Press the Start/Stop main menu key to activate the Vpp measurement.
Note 
The Vpp measurement is displayed in both Vpp and dBdsx.
The Vpp should meet the criteria of the service provider. When very close to the transmitter, the signal level must be 4.8 to 7.2 Vpp. Further from the transmitter, the Vpp will be lower.
 
Vpp Measurement