Land Mobile Radio Analyzer and Coverage Measurement Guide : DMR Analyzer (Option 591) : DMR Analyzer Graphs
 
DMR Analyzer Graphs
The following DMR Analyzer measurements are available on the LMR Master. From the Measurements main menu press DMR Analyzer twice. Press the Graph Type submenu key to select the measurement type.
Constellation and Linear Constellation
Constellation view displays the demodulation information in an IQ format (Figure: Constellation Diagram). The chart shows the relationship between the location of a constellation data point, its deviation frequency, and the information it carries.
Constellation Diagram
Figure: Linear Constellation Diagram shows the same information in the Linear Constellation View.
Linear Constellation Diagram
For input signals that are not DMR encoded, the LMR Master will still try to decode it and fit it to a symbol. This may cause some measurement results that are unexpected.
Histogram Graph
The Histogram graph displays a graphical representation of the symbols that are being received. The graph for each symbol represents the relative percentage that symbol was identified out of all the received symbols.
Each update of the screen is a separate representation of the latest data, rather than a cumulative total. The vertical scale is fixed at 0 % to 100 %, with each horizontal grid line representing 10 % of the total symbols received.
DMR Histogram
Spectrum Graph
The spectrum view displays a graphical representation of power (dBm) vs. frequency. The spectrum display gives an indication if there are interferers present that may degrade the bit error rate of the DMR signal. The frequency span is adjustable under the Frequency menu. The reference level is adjusted with the Amplitude menu. Refer to Amplitude Menu for details. Figure: DMR Spectrum Graph (25 kHz Span and 500 kHz Span) displays the same signal using a 25 kHz span and a 500 kHz span.
DMR Spectrum Graph (25 kHz Span and 500 kHz Span)
Eye Diagram
The eye diagram is an oscilloscope view of the DMR signal displaying the voltage of the signal vs. time. The diagram provides an indication of baseband fidelity of a DMR transmitter. With Over‑the‑air measurements the Eye Diagram can indicate phase distortion from multipath. The number of “eyes” displayed is set with the Symbol Span key under the Display Menu.
DMR Eye Diagram
Summary Graph and DMR Summary Graph
These two summary displays provide measured and decoded values in a table format.
Summary Graph
The summary graph provides an overview of a DMR transmitter. The graph displays numeric values of received power, frequency error, modulation fidelity (Mod Fid), bit error rate (BER), symbol deviation, Color Code (CC), and symbol rate error of the input signal.
The Received Power value in the summary graph can be toggled to dBm, watts, or volts by using the Amplitude > Units > Rx Units keys. This setting also applies to the squelch level setting.
The Setup > Squelch Lvl submenu key sets the squelch power level. When the Received Power is lower than the set squelch level, all summary graph measurements except for Received Pwr will be blanked out (--). When the Received Power is above the squelch level, the measurements will display as shown in Figure: Summary Table with Received Pwr Above the Squelch Level.
Summary Table with Received Pwr Above the Squelch Level
Received Pwr in the Summary table is the integrated power of all the energy in the receiver bandwidth. Any peak amplitude reduction seen in the Spectrum display when compared to Received Pwr is a function of the instruments RBW setting. The reduction is specified as: 10*Log (Signal Bandwidth / Resolution Bandwidth).
DMR Summary Graph
The DMR Summary graph reports the MS ID, Target ID, Talk Group ID, FID, Call Type, Base Station ID permitted on a channel from the DMR transmitter.
DMR Summary
 
Power Profile
The power profile graph is used with Mobile Station Rx Mod Type to display a zero‑span view of power vs. time of the selected Rx Slot.
DMR Power Profile