High (37–46 dBm) Output Power Press this submenu key to set the output power level within the higher range for both carrier frequencies, F1 and F2. Low (25–37 dBm) Output Power Press this submenu key to set the output power level within the lower range for both carrier frequencies, F1 and F2. Note: Power output value from the test port is twice the set output value. For example, when Setup > Output Power is set to 20 W, total output power is 40 W. 20 W (F1) + 20 W (F2) = 40 W Test Duration Press this submenu key to set the length of time that the test port will deliver power after Measurements > Test are pressed. Range for the test is 1 second to 1200 seconds. Use the Arrow keys or the number keypad. If you use the number keypad, then the Units Menu is displayed. Note: Test Duration does not apply when Enhanced Resolution is On. Normal‑>A Press this submenu key to display the current trace sweep, and to repeat the sweep. Max Hold‑>A Press this submenu key to display the maximum value for data points from continuous trace sweeps. Enhanced Resolution On Off Press this submenu key to toggle Enhanced Resolution On and Off. The default setting is On. Use this feature to resolve PIM sources that are physically close together. Up to 4 vertical impulse bars in the sweep window mark the predicted distance location of the measured PM sources. When On, DTP measurements are conducted one time only, then the measurement stops, and the result is displayed. DTP Aid |
s Press this submenu key after keying in a test duration (in seconds) with the number keypad. Pressing the Enter key also sets the value in seconds. Backspace Press this submenu key (after keying in a test duration with the number keypad) to delete the last digit. |