:SENSe{1-16}:IMD Subsystem
The :SENSe{1-16}:IMD Subsystem commands set configuration parameters for IMD and IMDView and controls normalization calibration for the indicated channel.
IMD Configuration and Setup Validation Steps
The IMD setup commands in this subsystem require a sequence of steps to configure and validate the setup:
1. Before changing any settings in the IMD subsystem, the command :SENSe{1-16}:IMD:CONFigure:DEFine[:STATe] must be set to ON .
2. After changing IMD subsystem settings, issue the :SENSe{1-16}:IMD:CONFigure command.
(Note: Define mode automatically turns off after issuing the :IMD:CONF command and the IMD mode is turned on.)
3. Issue the command :SENSe{1-16}:IMD:CONFigure:STATus? to get an explanation of any coercion that occurred.
:SENSe{1-16}:IMD:CONFigure
Description
This command is only available when IMD Define mode is enabled.
Configures and validates the IMD setup parameters on the indicated channel.
No query.
If one or more errors occur during validation, then a numeric error code will be added to the system error queue. In order to determine all error codes associated with the number returned by the command, use the following steps:
1. Find the largest number from the list below that is less than or equal to the number returned by the command. The error definition associated with that number has been triggered.
2. Subtract that number from the number returned by the command.
3. Repeat the process with the new number until you reach 0. All numbers found in this process that correspond to any in the list are the errors associated with the numeric error code.
For example, if the numeric error code returned is 18, you would find the next lower or equal number from the list (16), then subtract it from 18; in this case, 18–16 = 2. Then from the list find the next lower or equal number (2) and subtract it from the previous result; 2–2 = 0. So in this case, the errors associated with the number returned would be 16 (BadState), and 2 (OutOfRange).
1 = PowerOutOfRange
2 = OutOfRange
4 = PointsExceedMax
8 = PointsLessThanMin
16 = BadState
32 = FreqOutOfRange
64 = Tone1SetupInvalid
128 = Tone2SetupInvalid
256 = SetupNotSupported
512 = ToneSetupNotValidForCondor
1024 = InvalidIFBW
2048 = NoResponsesSelected
4096 = InvalidDelta
8192 = InvalidTonesConfiguration
16384 = InvalidResponse
32768 = Invalid
Cmd Parameters
NA
Query Parameters
NA
Range
NA
Default Value
NA
Syntax Example
:SENS1:IMD:CONF
:SENSe{1-16}:IMD:CONFigure:DEFine[:STATe] <char>
:SENSe{1-16}:IMD:CONFigure:DEFine[:STATe]?
Description
Sets the on/off state of the IMD configuration DEFINE mode on the indicated channel.
Returns the IMD configuration DEFINE mode state (on/off) on the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Parameters
NA
Query Output:
<char> 1 | 0
Range
NA
Default Value
0
Syntax Example
:SENS1:IMD:CONF:DEF 1
:SENS1:IMD:CONF:DEF?
:SENSe{1-16}:IMD:CONFigure:STATus?
Description
Query only.
Returns the IMD configuration and setup status on the indicated channel.
Cmd Parameters
NA
Query Parameters
NA
Query Output
<<Error description>>
Range
NA
Default Value
“Valid”
Syntax Example
:SENS1:IMD:CONF:STAT?
:SENSe{1-16}:IMD:DRVer:PORT?
Description
Query only.
Returns the driver port setting for the IMD mode on the indicated channel.
Cmd Parameters
NA
Query Parameters
NA
Query Output
<char> PORT1 | PORT2 | PORT3 | PORT4
Range
NA
Default Value
PORT1
Syntax Example
:SENS1:IMD:DRV:PORT?
:SENSe{1-16}:IMD:ENABled[:STATe] <char>
:SENSe{1-16}:IMD:ENABled[:STATe]?
Description
Sets the on/off state of the IMD mode on the indicated channel.
Returns IMD state (on/off) on the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Parameters
NA
Query Output:
<char> 1 | 0
Range
NA
Default Value
0
Syntax Example
:SENS1:IMD:ENAB ON
:SENS1:IMD:ENAB?
:SENSe{1-16}:IMD:GRANging:AUTO[:STATe] <char>
:SENSe{1-16}:IMD:GRANging:AUTO[:STATe]?
Description
The command is only available when IMD Define mode is enabled.
Sets the on/off state of the auto gain ranging for the IMD mode of the indicated channel.
Returns the on/off state of the auto gain ranging for the IMD mode of the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Parameters
NA
Query Output:
<char> 1 | 0
Range
NA
Default Value
1
Syntax Example
:SENS1:IMD:GRAN:AUTO OFF
:SENS1:IMD:GRAN:AUTO?
:SENSe{1-16}:IMD:GRANging:MGSTate <char>
:SENSe{1-16}:IMD:GRANging:MGSTate?
Description
The command is only available when IMD Define mode is enabled.
Sets the manual gain ranging for the IMD mode of the indicated channel.
Returns the manual gain ranging for the IMD mode of the indicated channel.
Cmd Parameters
<char> OFF | LOW | MED | HIGH
Query Parameters
NA
Query Output
<char> OFF | LOW | MED | HIGH
Range
NA
Default Value
OFF
Syntax Example
:SENS1:IMD:GRAN:MGST MED
:SENS1:IMD:GRAN:MGST?
:SENSe{1-16}:IMD:MODe <char>
:SENSe{1-16}:IMD:MODe?
Description
Sets the IMD mode on the indicated channel.
Returns the IMD mode on the indicated channel.
Currently available IMD modes:
SLINear = SpectrumView Linear Frequency Sweep
SFSegm = SpectrumView Frequency-based Segmented Sweep
FLINear = Frequency Mode Linear Frequency Sweep
Cmd Parameters
<char> SLINear | SFSegm | FLINear
Query Parameters
NA
Query Output
<char> SLIN | SFS | FLIN
Range
NA
Default Value
FLIN
Syntax Example
:SENS1:IMD:MOD SLIN
:SENS1:IMD:MOD?
:SENSe{1-16}:IMD:NCALibration:PERForm
Description
Performs IMD normalization calibration on the indicated channel.
No query.
Cmd Parameters
NA
Query Parameters
NA
Range
NA
Default Value
NA
Syntax Example
:SENS1:IMD:NCAL:PERF
:SENSe{1-16}:IMD:NCALibration[:STATe] <char>
:SENSe{1-16}:IMD:NCALibration[:STATe]?
Description
Sets the on/off state of IMD normalization calibration on the indicated channel.
Returns the on/off status of IMD normalization calibration on the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Output:
<char> 1 | 0
Query Parameters
NA
Range
NA
Default Value
0
Syntax Example
:SENS1:IMD:NCAL:STAT 0
:SENS1:IMD:NCAL:STAT?
:SENSe{1-16}:IMD:PARameter{1-16}:DISPlay <char>
:SENSe{1-16}:IMD:PARameter{1-16}:DISPlay?
Description
Sets the on/off state of the trace display for the particular trace on the indicated channel.
Returns the trace display status (On/Off) for the particular trace on the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Parameters
NA
Query Output:
<char> 1 | 0
Range
NA
Default Value
1
Syntax Example
:SENS1:IMD:PAR2:DISP 0
:SENS1:IMD:PAR2:DISP?
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:ORDer <char>
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:ORDer?
Description
The command is only available when IMD Define mode is enabled.
The command not valid in IMD SpectrumView mode.
Sets the response order for the given trace in IMD mode of the indicated channel.
Returns the response order for the given trace in IMD mode of the indicated channel.
Cmd Parameters
<char> FIRSt | SECond | THIRd | FIFTh | SEVenth | NINTh
Query Parameters
NA
Query Output
FIRS | SEC | THIR | FIFT | SEV | NINT
Range
NA
Default Value
Syntax Example
:SENS1:IMD:PAR2:RESP:ORD THIR
:SENS1:IMD:PAR2:RESP:ORD?
:IMD:PARameter{1-16}:RESPonse Commands – Default Values
Trace #
Type
Order
Side
Ref Plane
Ref Type
Display
1
IPO
THIR
PAVG
OUTP
PAVG
ON
2
TPOW
FIRS
PAVG
OUTP
PAVG
ON
3
TPOW
THIR
FLOW
OUTP
PAVG
ON
4
TPOW
THIR
FHIG
OUTP
PAVG
ON
5 to 16
IPO
THIR
PAVG
OUTP
PAVG
OFF
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:REFerence:PLANe <char>
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:REFerence:PLANe?
Description
The command is only available when IMD Define mode is enabled.
The command not valid in IMD SpectrumView mode.
Sets the response reference plane for the given trace in IMD mode of the indicated channel.
Returns the response reference plane for the given trace in IMD mode of the indicated channel.
Cmd Parameters
<char> INPut | OUTPut
Query Parameters
NA
Query Output
INP | OUTP
Range
NA
Default Value
Syntax Example
:SENS1:IMD:PAR2:RESP:REF:PLAN OUTP
:SENS1:IMD:PAR2:RESP:REF:PLAN?
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:REFerence:TYPE <char>
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:REFerence:TYPE?
Description
The command is only available when IMD Define mode is enabled.
The command not valid in IMD SpectrumView mode.
Sets the response reference type for the given trace in IMD mode of the indicated channel.
Returns the response reference type for the given trace in IMD mode of the indicated channel.
Currently available Reference Types:
FLOWer = Frequency Lower FHIGher = Frequency Higher PAVG = Power Average PLOWer = Power Lower PHIGher = Power Higher
Cmd Parameters
<char> FLOWer | FHIGher | PAVG | PLOWer | PHIGher
Query Parameters
NA
Query Output
FLOW | FHIG | PAVG | PLOW | PHIG
Range
NA
Default Value
Syntax Example
:SENS1:IMD:PAR2:RESP:REF:TYPE PLOW
:SENS1:IMD:PAR2:RESP:REF:TYPE?
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:SIDE <char>
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:SIDE?
Description
The command is only available when IMD Define mode is enabled.
The command not valid in IMD SpectrumView mode.
Sets the response side for the given trace in IMD mode of the indicated channel.
Returns the response side for the given trace in IMD mode of the indicated channel.
Currently available Sides:
FLOWer = Frequency Lower FHIGher = Frequency Higher PAVG = Power Average PLOWer = Power Lower PHIGher = Power Higher
Cmd Parameters
<char> FLOWer | FHIGher | PAVG | PLOWer | PHIGher
Query Parameters
NA
Query Output
FLOW | FHIG | PAVG | PLOW | PHIG
Range
NA
Default Value
Syntax Example
:SENS1:IMD:PAR2:RESP:SIDE PLOW
:SENS1:IMD:PAR2:RESP:SIDE?
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:TYPE <char>
:SENSe{1-16}:IMD:PARameter{1-16}:RESPonse:TYPE?
Description
The command is only available when IMD Define mode is enabled.
When in SpectrumView mode, the Response Type return will be TonePower.
Sets the Response Type for the given trace in IMD mode of the indicated channel.
Returns the Response Type for the given trace in IMD mode of the indicated channel.
Currently available Response types:
TPOWer = Tone Power RTCarrier = Relative To Carrier IPOint = Intercept Point TGAin = Tone Gain ASYMmetry = Asymmetry
Cmd Parameters
<char> TPOWer | RTCarrier | IPOint | TGAin | ASYMmetry
Query Parameters
NA
Query Output
TPOW | RTC | IPO | TGA | ASYM
Range
NA
Default Value
Syntax Example
:SENS1:IMD:PAR2:RESP:TYPE TPOW
:SENS1:IMD:PAR2:RESP:TYPE?
:SENSe{1-16}:IMD:POINts <NRf>
:SENSe{1-16}:IMD:POINts?
Description
The command is only available when IMD Define mode is enabled.
This command does not apply when IMD is set to perform a SpectrumView measurement.
Sets the number of points to be used in the IMD measurement on the specified channel.
Returns the number of points used in the IMD measurement on the specified channel.
Cmd Parameters
<NRf> The input number of points value.
Query Parameters
NA
Query Output
<NR1> The output number of points value.
Range
2 to instrument number of points setting (25000)
Default Value
201
Syntax Example
:SENS1:IMD:POIN 50
:SENS1:IMD:POIN?
:SENSe{1-16}:IMD:POWer:PORT:COUPle[:STATe] <char>
:SENSe{1-16}:IMD:POWer:PORT:COUPle[:STATe]?
Description
The command is only available when IMD Define mode is enabled.
Sets the on/off state of the coupled port power of the indicated channel.
Returns the on/off state of the coupled port power of the indicated channel.
Cmd Parameters
<char> 1 | 0 | ON | OFF
Query Parameters
NA
Query Output:
<char> 1 | 0
Range
NA
Default Value
1
Syntax Example
:SENSe1:IMD:POWer:PORT:COUPle ON
:SENSe1:IMD:POWer:PORT:COUPle?
:SENSe{1-16}:IMD:PRODuct:IFBW <NRf>
:SENSe{1-16}:IMD:PRODuct:IFBW?
Description
The command is only available when IMD Define mode is enabled.
Sets the product IFBW of IMD mode on the indicated channel.
Returns the product IFBW of IMD mode on the indicated channel.
Cmd Parameters
<NRf> The input IFBW product value
Query Parameters
NA
Query Output
<NR1> The output IFBW product value
Range
1 Hz to 1 MHz
Default Value
1 kHz
Syntax Example
:SENS1:IMD:PROD:IFBW 10
:SENS1:IMD:PROD:IFBW?
:SENSe{1-16}:IMD:RECeiver:PORT:SELect <char>
:SENSe{1-16}:IMD:RECeiver:PORT:SELect?
Description
The command is only available when IMD Define mode is enabled.
The use of Port 3 and/or Port 4 requires a 4-port VNA instrument.
Sets the receiver port of the IMD mode of the indicated channel.
Returns the receiver port of the IMD mode of the indicated channel.
Cmd Parameters
<char> PORT1 | PORT2 | PORT3 | PORT4
Query Parameters
NA
Query Output
<char> PORT1 | PORT2 | PORT3 | PORT4
Range
NA
Default Value
PORT2
Syntax Example
:SENS1:IMD:REC:PORT:SEL PORT1
:SENS1:IMD:REC:PORT:SEL?
:SENSe{1-16}:IMD:SPECtrum:DELTa <NRf>
:SENSe{1-16}:IMD:SPECtrum:DELTa?
Description
Sets the delta of SpectrumView IMD mode of the indicated channel.
Returns the delta of SpectrumView IMD mode of the indicated channel.
Cmd Parameters
<NRf> The input delta value of SpectrumView IMD mode.
Query Parameters
NA
Query Output
<NR3> The output delta value of SpectrumView IMD mode.
Range
Varies based on instrument models and options.
Default Value
3 MHz
Syntax Example
:SENS1:IMD:SPEC:DELT 10
:SENS1:IMD:SPEC:DELT?
:SENSe{1-16}:IMD:SPECtrum:FREQuency <NRf>
:SENSe{1-16}:IMD:SPECtrum:FREQuency?
Description
Sets the center frequency of SpectrumView IMD mode of the indicated channel.
Returns the center frequency of SpectrumView IMD mode of the indicated channel.
Cmd Parameters
<NRf> The input center frequency value.
Query Parameters
NA
Query Output
<NR3> The output center frequency value.
Range
Varies based on instrument models and options.
Default Value
1 GHz
Syntax Example
:SENS1:IMD:SPEC:FREQ 1.0E9
:SENS1:IMD:SPEC:FREQ?
:SENSe{1-16}:IMD:SPECtrum:ORDer <char>
:SENSe{1-16}:IMD:SPECtrum:ORDer?
Description
The command is only available when IMD Define mode is enabled.
Sets the highest order of SpectrumView (linear frequency) IMD mode on the indicated channel.
Returns the highest order of SpectrumView (linear frequency) IMD mode on the indicated channel.
Cmd Parameters
<char> FIRSt | SECond | THIRd | FIFTh | SEVenth | NINTh
Query Parameters
NA
Query Output
FIRS | SEC | THIR | FIFT | SEV | NIN
Range
NA
Default Value
NIN
Syntax Example
:SENS1:IMD:SPEC:ORD THIR
:SENS1:IMD:SPEC:ORD?
:SENSe{1-16}:IMD:SPECtrum:SEGMented:SECond:ORDer[:STATe] <char>
:SENSe{1-16}:IMD:SPECtrum:SEGMented:SECond:ORDer[:STATe]?
Description
The command is only available when IMD Define mode is enabled.
Sets the on/off state of the option to include second order of SpectrumView – segmented IMD mode on the indicated channel.
Returns the second order setting (On/Off) of SpectrumView – segmented IMD mode on the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Parameters
NA
Range
NA
Default Value
0
Syntax Example
:SENS1:IMD:SPEC:SEGM:SEC:ORD:STAT ON
:SENS1:IMD:SPEC:SEGM:SEC:ORD:STAT?
:SENSe{1-16}:IMD:SPECtrum:TONE1:POWer <NRf>
:SENSe{1-16}:IMD:SPECtrum:TONE1:POWer?
Description
Sets the tone 1 power of SpectrumView IMD mode of the indicated channel.
Returns the tone 1 power of SpectrumView IMD mode of the indicated channel.
Cmd Parameters
<NRf> The input tone 1 power value.
Query Parameters
NA
Query Output
<NR3> The output tone 1 power value.
Range
See power range and default for internal sources for your VNA model.
For external synthesizers, default is 0 dBm and range is set by synthesizer limits.
(Note: Max source power is 20 dBm if Option 31 Second Source is installed.)
Default Value
See notes on Range above.
Syntax Example
:SENS1:IMD:SPEC:TONE1:POW 10
:SENS1:IMD:SPEC:TONE1:POW?
:SENSe{1-16}:IMD:SPECtrum:TONE2:POWer <NRf>
:SENSe{1-16}:IMD:SPECtrum:TONE2:POWer?
Description
Sets the tone 2 power of SpectrumView IMD mode of the indicated channel.
Returns the tone 2 power of SpectrumView IMD mode of the indicated channel.
Cmd Parameters
<NRf> The input tone 2 power value.
Query Parameters
NA
Query Output
<NR3> The output tone 2 power value.
Range
See power range and default for internal sources for your VNA model.
For external synthesizers, default is 0 dBm and range is set by synthesizer limits.
(Note: Max source power is 20 dBm if Option 31 Second Source is installed.)
Default Value
See notes on Range above.
Syntax Example
:SENS1:IMD:SPEC:TONE2:POW 10
:SENS1:IMD:SPEC:TONE2:POW?
:SENSe{1-16}:IMD:SPUR:AVOidance[:STATe] <char>
:SENSe{1-16}:IMD:SPUR:AVOidance[:STATe]?
Description
The command is only available when IMD Define mode is enabled.
Sets the on/off state of the option to avoid spur on the indicated channel.
Returns the avoid spur status (On/Off) in IMD configuration on the indicated channel.
Cmd Parameters
<char> ON | OFF | 1 | 0
Query Parameters
NA
Query Output:
<char> 1 | 0
Range
NA
Default Value
1
Syntax Example
:SENS1:IMD:SPUR:AVO 0
:SENS1:IMD:SPUR:AVO?
:SENSe{1-16}:IMD:SWEPt:DELTa <NRf>
:SENSe{1-16}:IMD:SWEPt:DELTa?
Description
Sets the delta of swept frequency IMD mode of the indicated channel.
Returns the delta of swept frequency IMD mode of the indicated channel.
Cmd Parameters
<NRf> The input delta value of swept frequency IMD mode
Query Parameters
NA
Query Output
<NR3> The output delta value of swept frequency IMD mode
Range
Varies based on instrument models and options
Default Value
3 MHz
Syntax Example
:SENS1:IMD:SWEP:DELT 10
:SENS1:IMD:SWEP:DELT?
:SENSe{1-16}:IMD:SWEPt:FREQuency:STARt <NRf>
:SENSe{1-16}:IMD:SWEPt:FREQuency:STARt?
Description
Sets the center start frequency of swept frequency IMD mode of the indicated channel.
Returns the center start frequency of swept frequency IMD mode of the indicated channel.
Cmd Parameters
<NRf> The center start frequency value.
Query Parameters
NA
Query Output
<NR3> The center start frequency value.
Range
Varies based on instrument models and options.
Default Value
Varies based on instrument models and options.
Syntax Example
:SENS1:IMD:SWEP:FREQ:STAR 1E9
:SENS1:IMD:SWEP:FREQ:STAR?
:SENSe{1-16}:IMD:SWEPt:FREQuency:STOP <NRf>
:SENSe{1-16}:IMD:SWEPt:FREQuency:STOP?
Description
Sets the center stop frequency of swept frequency IMD mode of the indicated channel.
Returns the center stop frequency of swept frequency IMD mode of the indicated channel.
Cmd Parameters
<NRf> The center stop frequency value.
Query Parameters
NA .
Query Output
<NR3> The center stop frequency value
Range
Varies based on instrument models and options.
Default Value
Varies based on instrument models and options.
Syntax Example
SENS1:IMD:SWEP:FREQ:STOP 1E9
SENS1:IMD:SWEP:FREQ:STOP?
:SENSe{1-16}:IMD:SWEPt:TONE1:POWer <NRf>
:SENSe{1-16}:IMD:SWEPt:TONE1:POWer?
Description
Sets the tone 1 power of swept frequency IMD mode of the indicated channel.
Returns the tone 1 power of swept frequency IMD mode of the indicated channel.
Cmd Parameters
<NRf> The tone 1 power value.
Query Parameters
NA
Query Output
<NR3> The tone 1 power value.
Range
See power range and default for internal sources for your VNA model.
For external synthesizers, default is 0 dBm and range is set by synthesizer limits.
(Note: Max source power is 20 dBm if Option 31 Second Source is installed.)
Default Value
See notes on Range above.
Syntax Example
:SENS1:IMD:SWEP:TONE1:POW 10
:SENS1:IMD:SWEP:TONE1:POW?
:SENSe{1-16}:IMD:SWEPt:TONE2:POWer <NRf>
:SENSe{1-16}:IMD:SWEPt:TONE2:POWer?
Description
Sets the tone 2 power of swept frequency IMD mode of the indicated channel.
Returns the tone 2 power of swept frequency IMD mode of the indicated channel.
Cmd Parameters
<NRf> The tone 2 power value
Query Parameters
NA
Query Output
<NR3> The tone 2 power value
Range
See power range and default for internal sources for your VNA model.
For external synthesizers, default is 0 dBm and range is set by synthesizer limits.
(Note: Max source power is 20 dBm if Option 31 Second Source is installed.)
Default Value
See notes on Range above.
Syntax Example
:SENS1:IMD:SWEP:TONE2:POW 10
:SENS1:IMD:SWEP:TONE2:POW?
:SENSe{1-16}:IMD:TONE1:SOURce <char>
:SENSe{1-16}:IMD:TONE1:SOURce?
Description:
The command is only available when IMD Define mode is enabled.
Sets the tone 1 source of the IMD mode on the indicated channel.
Returns the tone 1 source of the IMD mode on the indicated channel.
Cmd Parameters
Query Parameters:
NA
Query Output
Min-Max Range
NA
Default Value
DT1
Syntax Example
:SENS1:IMD:TONE1:SOUR S2T1
:SENS1:IMD:TONE1:SOUR?
:SENSe:IMD:TONE{1-2}:SOURce Command/Query Output Variables (1 of 2)
Query Output Value
Standard
No Opt 31
Standard
With Opt. 31
3739 Test Set
No Opt 31
Freq range >54G
3739 Test Set
With Opt. 31
Freq range > 54G
3739 Test Set
No Opt 31
Freq range ≤ 54G
3739 Test Set
With Opt 31
Freq range ≤ 54G
DT1
(Default To 1)
Int Src -> Port 1
Src 1 -> Port 1
Int Src -> Mod 1
Src 1 -> Aux Mod
Int Src -> Mod 1
Src 1 -> Mod 1
S2T1
(Source2 to 1)
N/A
Src 2 -> Port 1 (Only applicable if Opt.32 present)
N/A
Src 2->Mod 1
N/A
Src 2 -> Mod 1 (Only applicable if Opt 32 present)
DT2
(Default to 2)
Int Src -> Port 2
Src 2 -> Port 2
Int Src -> Mod 2
Src 2 -> Mod 2
Int Src -> Mod 2
Src 2 -> Mod 2
DT3
(Default to 3)
Int Src -> Port 3
Src 2->Port 3
Int Src -> Mod 3
Src 3 -> Mod 3
Int Src -> Mod 3
Src 3 -> Mod 3
DT4
(Default to 4)
Int Src -> Port 4
Src 4->Port 4
Int Src -> Mod 4
Src 4 -> Mod 4
Int Src -> Mod 4
Src 4 -> Mod 4
EXT1
Ext Source 1
Ext Source 1
Ext Synth 1 -> Aux Mod
Ext Synth 1 -> Aux Mod
Ext Synth 1
Ext Synth 1
EXT2
Ext Source 2
Ext Source 2
Ext Synth 2 -> Aux Mod
Ext Synth 2 -> Aux Mod
Ext Synth 2
Ext Synth 2
EXT3
Ext Source 3
Ext Source 3
Ext Synth 3 -> Aux Mod
Ext Synth 3 -> Aux Mod
Ext Synth 3
Ext Synth 3
EXT4
Ext Source 4
Ext Source 4
Ext Synth 4 -> Aux Mod
Ext Synth 4 -> Aux Mod
Ext Synth 4
Ext Synth 4
:SENSe{1-16}:IMD:TONE2:SOURce <char>
:SENSe{1-16}:IMD:TONE2:SOURce?
Description:
The command is only available when IMD Define mode is enabled.
Sets the tone 2 source of the IMD mode on the indicated channel.
Returns the tone 2 source of the IMD mode on the indicated channel.
Cmd Parameters
Query Parameters:
NA
Query Output
Min-Max Range
NA
Default Value
S2T1 (If option 31 and 32 is available.)
DT2 (If option 31 is available but option 32 is not available.)
EXT1 (If option 31 is not available.)
Syntax Example
:SENS1:IMD:TONE2:SOUR EXT2
:SENS1:IMD:TONE2:SOUR?
:SENSe{1-16}:IMD:TONe:IFBW <NRf>
:SENSe{1-16}:IMD:TONe:IFBW?
Description
The command is only available when IMD Define mode is enabled.
Sets the tone IFBW of IMD mode on the indicated channel.
Returns the tone IFBW of IMD mode on the indicated channel.
Cmd Parameters
<NRf> The input IFBW tone value
Query Parameters
NA
Query Output
<NR1> The output IFBW tone value
Range
1 Hz to 1 MHz
Default Value
1 kHz
Syntax Example
:SENS1:IMD:TON:IFBW 10
:SENS1:IMD:TON:IFBW?
1-800-ANRITSU
10450-00040 Rev. AD