Mode Toggles the mode between Point by Point (PBP) and Full Time Record (FTR). Notes: Depending on the mode selected, the time parameters change from Delay (for PBP) to Start/Stop (for FTR). The bottom trace display status bar indicates the Advanced Fast CW mode (FCW-PBP or FCW-FTR): Synch Interval Select activates a toolbar for setting synchronization interval. Capture Duration Select activates a toolbar for setting capture duration in time units. Measurement Width Select activates a toolbar for setting measurement width in time units. Delay (Point by Point mode only) Select activates a toolbar for setting delay in time units. Start Time (Full Time Record mode only) Select activates a toolbar for setting start time Stop Time (Full Time Record mode only) Select activates a toolbar for setting stop time # of Points Select activates a toolbar for setting the number of points measured from Start to Stop time. Trigger Source Displays the trigger source that is selected from Other Setup (Addl.FCW Setup) menu. Note that this becomes active as a manual trigger button when Trigger Source is set to Manual. Additional Fast CW Setup Select opens the Addl.FCW Setup menu for more Fast CW setup parameters. See Addl. FCW SETUP Menu. |
Ext Synch Marking Select opens the External Synch Marking Menu. Raw Data Export Select opens the Raw Data Export Menu. Receiver Select opens the Receiver Menu. Rcvr Coupling Select toggles receiver coupling ON and OFF. Sampling Interval Select activates a toolbar for entering desired sampling interval. Trigger Source Select opens the Trigger Source Menu. External Trigger Setup Select opens the External Trigger Setup Menu. Manual Trigger Setup Select opens the Manual Trigger Setup Menu. GPIB Trigger Setup Select opens the GPIB Trigger Setup Menu. |
OFF Internal synch is active when OFF is selected. External Rising External synch based on the rising edge of the signal present at the Synch In port on the rear panel. External Falling External synch based on the falling edge of the signal present at the Synch In port on the rear panel. |
OFF Select disables Raw Data Export. Binary Select allows data export in binary format. See the Measurement Guide for details on this format. HDF5 (.mat) (HDF5 currently not supported; to be supported in later release.) Binary File Path Select opens a browsing dialog to designate the file path. HDF5 File Name (HDF5 currently not supported; to be supported in later release.) |
A1 Receiver Selects the A1 receiver. A2 Receiver Selects the A2 receiver. B1 Receiver Selects the B1 receiver. B2 Receiver Selects the B2 receiver. |
A1 Receiver Selects the A1 receiver. A2 Receiver Selects the A2 receiver. A3 Receiver Selects the A3 receiver. A4 Receiver Selects the A4 receiver. B1 Receiver Selects the B1 receiver. B2 Receiver Selects the B2 receiver. B3 Receiver Selects the B3 receiver. B4 Receiver Selects the B4 receiver. |
Internal Select sets triggering to be automatically created within the instrument. Internal triggering mode is an automatically triggered point-by-point measurement that is controlled by the instrument internal software. Manual Select sets triggering to be manually triggered by the user from the Fast CW SETUP Menu. The default setting is on a per-channel basis. The maximum setting is for all channels. External Select sets triggering to be created externally by another instrument and sensed through an external port/connector. GPIB Select sets triggering to be through an external GPIB device and communicated to the instrument via a GPIB network. |
Trig. All Chan. The Trigger All Channels button sets the external trigger to measure values for all channels. Trig. One Chan. The Trigger One Channel button sets the external trigger to measure values for one channel only. Trig. One Sweep The Trigger One Sweep button sets the external trigger to measure values for one sweep only. Trig. One Point The Trigger One Point sets the external trigger to measure values for one point only. Trigger Delay (Time) Trigger delay sets the time interval between when the instrument received the trigger signal and when the triggered measurement starts. Select displays the Trigger Delay field toolbar and allows the user to enter a trigger delay time and select units. Trigger On (Positive Edge/Negative Edge) (External Trigger) Select toggles the triggering point to be on either the positive edge or negative edge of the triggering signal. The default value is positive edge. Trigger Handshake (Off/On) (External Trigger) If triggering handshaking is on, the instrument provides a Ready for Trigger and an Output Trigger signal from the rear panel. • The instrument sends a Ready for Trigger signal to specify if the instrument is ready or not to receive a triggering signal. • The instrument sends an Output Trigger signal when the triggered measurement is complete. Select toggles whether the trigger handshake is off or on. The default value is OFF. |
Trig. All Chan. The Trigger All Channels button sets the trigger to measure values for all channels. Trig. One Chan. The Trigger One Channel button sets the trigger to measure value for the active channel only. Trig. One Sweep The Trigger One Sweep button sets the trigger to measure values for one sweep only. Trig. One Point The Trigger One Point button sets the trigger to measure values for one point only. |
Trig. All Chan. The Trig. All Chan. button triggers a measurement for all channels. Trig. One Chan. The Trig. One Chan. button triggers a measurement for the active channel only. Trig. One Sweep The Trig. One Sweep button triggers a measurement for one sweep only. Trig. One Point The Trig. One Point button triggers a measurement for one point only. |