• The VNA measurement mode at the APPLICATION menu is not set to Noise Figure.
3. RESPONSE Menu – 2-Port VNA
• Noise Figure is equipped; Option 41 or 48.
• The VNA measurement mode at the APPLICATION menu is set to Noise Figure.
• The User-Defined button is unavailable.
• The Mixed-Mode button is unavailable.
4. Response Menu – 4-Port VNA
• Option 41/48 – Noise Figure is not equipped.
• Optical Measurements is ON.
5. IMD RESPONSE Menu – 2-Port VNA
• Option 44 – IMDView active.
Button Selection Group
• All the buttons of the RESPONSE menu, except for the Analog In Cal button, form a button selection group where the selection of any one button de-selects the other buttons.
S11 (Response)
Select sets the response to the input reflection coefficient (or S11 Forward Reflection) and de-selects S12, S21, S22, User-defined, Mixed-Mode, Ext. Analog In 1, and Ext. Analog In 2.
S12 (Response)
Select sets the response to the reverse transmission coefficient (or S12 Reverse Transmission) and de-selects S12, S21, S22, User-defined, Mixed-Mode, Ext. Analog In 1, and Ext. Analog In 2.
S21 (Response)
Select sets the response to the forward transmission coefficient (or S21 Forward Transmission) and de-selects S12, S21, S22, User-defined, Mixed-Mode, Ext. Analog In 1, and Ext. Analog In 2.
S22 (Response)
Select sets the response to the output reflection coefficient (or S22 Reverse Reflection) and de-selects S12, S21, S22, User-defined, Mixed-Mode, Ext. Analog In 1, and Ext. Analog In 2.
User-defined (Response)
Select displays the USER-DEFINED menu and sets the response to a user-defined mathematical fraction by using the USERDEFINED menu to select S11, S12, S21, S22, or 1 (one) as a numerator over S11, S12, S21, S22, or 1 as the denominator. Select also de-selects S12, S21, S22, Mixed-Mode, Ext. Analog In 1, and Ext. Analog In 2. This button is unavailable if the VNA measurement mode at the APPLICATION menu is set to Noise Figure. Option 41 or Option 48 must be equipped for Noise Figure.
Select displays the MIXED-MODE menu where mixed-mode response options of SDD, SCC, SDC, and SCD are available with a Port Pair assignment of either 1:2 or 2:1. Select also de-selects S12, S21, S22, User-Defined, Ext. Analog In 1, and Ext. Analog In 2. This button is unavailable if the VNA measurement mode at the APPLICATION menu is set to Noise Figure. Option 41 or Option 48 must be equipped for Noise Figure.
This button is only present if Option 41 – Noise Figure or Option 48 – Differential Noise Figure is equipped on the VNA. If present, it is only available if the VNA application mode is set to Noise Figure. The application mode is set on the APPLICATION menu at: