PIM Master™ Passive Intermodulation Analyzer with Site Master™ Cable & Antenna Analyzer (331) and 2-Port Options (703) User Guide : Wireless Remote Control : Using a ZyXEL MWR102 Travel Router : Configuring PIM Master for use with Router
 
Configuring PIM Master for use with Router
Configuring the MW82119B PIM Master for use with a Portable Router (such as ZyXEL MWR102 or equivalent).
1. Press Shift and System (8) to display the System Menu.
2. Press the System Options submenu key, then the Ethernet Config submenu key.
3. Configure the Ethernet connection. The example IP address is 192.168.100.5 in Figure: Example of Entering Ethernet IP Address.
Figure: Example of Entering Ethernet IP Address is an example of the Ethernet Editor. Your information night be different. For example, 255.255.255.0 should be the subnet mask.
For additional configuration instructions, refer to Ethernet Configuration in Appendix H, “LAN and DHCP”.
Example of Entering Ethernet IP Address
4. Ensure that your wireless device (phone, tablet, laptop) is connected to the router. Then launch your browser.
5. Enter the PIM Master IP address in the browser URL field, and wait while the connection is made.
 
6. When the browser connection is complete, the initial instrument control window is displayed (see Figure: Example of Browser Control Window). This window provides instrument status information.
The example IP address (192.168.100.5) appears in the title bar of the instrument control window (as shown in Figure: Example of Browser Control Window).