Note | Not all after-market USB drives are compatible with Field Master Pro. The USB drive must contain a single partition using either FAT32, exFAT, NTFS and ext4 file formats. |
Model | Frequency Range |
MS2090A‑0709 | Spectrum Analyzer, 9 kHz to 9 GHz |
MS2090A‑0714 | Spectrum Analyzer, 9 kHz to 14 GHz |
MS2090A‑0720 | Spectrum Analyzer, 9 kHz to 20 GHz |
MS2090A‑0726 | Spectrum Analyzer, 9 kHz to 26.5 GHz |
MS2090A‑0732 | Spectrum Analyzer, 9 kHz to 32 GHz |
MS2090A‑0743 | Spectrum Analyzer, 9 kHz to 43.5 GHz |
MS2090A‑0754 | Spectrum Analyzer, 9 kHz to 54 GHz |
Option1 | Description |
MS2090A‑0003 | Time-domain Reflectometry Measurement |
MS2090A‑0006 | Remove Wi-Fi and Bluetooth™ |
MS2090A‑0017 | Secure Communication |
MS2090A‑0019* | High Accuracy Power Meter (requires compatible USB power sensor, sold separately) |
MS2090A‑0024* | Interference Finder |
MS2090A‑0027* | Channel Scanner |
MS2090A‑0031* | GNSS Receiver (requires external GNSS antenna) |
MS2090A-0089* | Zero Span IF Output |
MS2090A-0090* | Gated Sweep |
MS2090A-0103* | 55 MHz Analysis Bandwidth |
MS2090A-0104* | 110 MHz Analysis Bandwidth |
MS2090A-0124* | IQ Waveform Capture (Includes MX280005A IQ Signal Master base feature set) |
MS2090A-0125* | IQ Waveform Streaming (Includes MX280005A IQ Signal Master base feature set) (Requires Option 124) |
MS2090A-0126* | IQ Waveform Capture (Includes MX280005A IQ Signal Master base feature set) (Non-Export Controlled) |
MS2090A-0127* | IQ Waveform Streaming (Includes MX280005A IQ Signal Master base feature set) (Requires Option 126, Non-Export Controlled) |
MS2090A-0128* | Vector Signal Analysis Enabled (requires Option 124 or 126; use with MX280005A) |
MS2090A-0199* | Real-Time Spectrum Analysis (RTSA) |
MS2090A-0331* | Cable and Antenna Analyzer (requires Site Master S331P analyzer, sold separately) |
MS2090A-0400* | Enable Vision Monitor |
MS2090A-0401* | Enable Vision Locate (requires Option 400) |
MS2090A-0407* | Enable Vision High-Speed Port Scanner |
MS2090A-0421* | Pulse Analyzer |
MS2090A-0431* | Coverage Mapping (requires Option 31) |
MS2090A-0444* | EMF Measurement (requires a compatible Anritsu isotropic antenna) |
MS2090A-0445* | EMF Meter Enabled (requires 2000-1985-R isotropic EMF probe) |
MS2090A-0509* | AM/FM Modulation Measurements |
MS2090A-0871* | WCDMA FDD Measurements (requires Option 31) |
MS2090A-0883* | LTE FDD/TDD Measurement (requires Option 31) |
MS2090A-0888* | 5GNR Downlink Measurements (requires Option 31) |
MS2090A‑xxxx-0097 | Accredited Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate, test report, and uncertainty data. |
MS2090A‑xxxx-0098 | Standard Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate. |
MS2090A‑xxxx-0099 | Premium Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate, test report, and uncertainty data. |
* Timed-Limited Options | Options marked with an asterisk are offered as a 90-day time limited option by ordering as a -9xxx series option. For example, MS2090A-9888 is the 90-day time limited option for 5GNR FDD/TDD Measurements. The option start time begins when the user first activates the option. |
Model | Description |
MX280001A | Vision™ Software |
MX280005A | IQ Signal Master™ Vector Signal Analysis Software |
MX280007A | Mobile InterferenceHunter™ Software |
ARRT | Anritsu Remote and Report Tools |