VectorStar™ MS4640A SeriesMicrowave Vector Network Analyzer : SCPI Commands : :SENSe{1-16}:CORRection:COLLect:WAVeguide Subsystem
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide Subsystem
The :SENSe{1-16}:CORRection:COLLect:WAVeguide subsystem sets the calibration parameters and coefficients for waveguide line types. Use this subsystem to set waveguide parameters before starting a calibration.
Calibration Setup Subsystems
These subsystems are used during various phases of calibration configuration setup:
:CALCulate{1-16}:IMPedance:TRANsformation Subsystem
:CALCulate{1-16}:REFerence Subsystem
:SENSe{1-16}:CORRection:COLLect:METHod Subsystem
:SENSe{1-16}:CORRection:COLLect:MICrostrip Subsystem
:SENSe{1-16}:CORRection:COLLect:MULTIple Subsystem
:SENSe{1-16}:CORRection:COLLect Subsystem
:SENSe{1-16}:CORRection:COLLect:WAVeguide Subsystem
:SENSe{1-16}:CORRection:COLLect[:CALa]:PORT Subsystem
:SENSe{1-16}:CORRection:ISOLation Subsystem
:SENSe{1-16}:CORRection:STATe Subsystem
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:DIELectric <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:DIELectric?
Description
Sets the waveguide calibration kit dielectric value on the indicated channel. Outputs the waveguide calibration kit dielectric value on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is a unitless number.
Query Parameters
<NR3> The output parameter is a unitless number.
Range
MPND
Default Value
1.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:DIEL 1.2E0
:SENS1:CORR:COLL:WAV:DIEL?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:FREQuency <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:FREQuency?
Description
Sets the waveguide calibration kit cutoff frequency on the indicated channel. Outputs the waveguide calibration kit cutoff frequency on the indicated channel.
Cmd Parameters
<NRf> The input parameter is Hertz.
Query Parameters
<NR3> The output parameter is in Hertz.
Range
MPND
Default Value
See Calibration Component Parameters.
Syntax Example
:SENS1:CORR:COLL:WAV:FREQ 5.0E9
:SENS1:CORR:COLL:WAV:FREQ?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:KIT <char1>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:KIT?
Description
Sets the waveguide kit type on the indicated channel. Outputs the waveguide kit type on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<char1> WR10 | WR12 | WR15 | USER1 | USER2 | USER3 | USER4 | USER5 | USER6 | USER7 | USER8 | USER9 | USER10 | USER11 | USER12 | USER13 | USER14 | USER15 | USER16 | USER17 | USER18 | USER19 | USER20 | USER21 | USER22 | USER23 | USER24 | USER25 | USER26 | USER27 | USER28 | USER29 | USER30 | USER31 | USER32
Where:
WR10 = Typical WR-10 RF waveguide
WR12 = Typical WR-12 RF waveguide
WR15 = Typical WR-13 RF waveguide
USER1 = User defined waveguide 1. The device can be renamed by the user but programmatically is always referred to as “USER1”.
USER2 = User-defined waveguide 2. The device can be renamed by the user but programmatically is always referred to as “USER2”;
through
USER32 = User-defined waveguide 32. The device can be renamed by the user but programmatically is always referred to as “USER32”.
Query Parameters
<char1> WR10 | WR12 | WR15 | USER1 | USER2 | USER3 | USER4 | USER5 | USER6 | USER7 | USER8 | USER9 | USER10 | USER11 | USER12 | USER13 | USER14 | USER15 | USER16 | USER17 | USER18 | USER19 | USER20 | USER21 | USER22 | USER23 | USER24 | USER25 | USER26 | USER27 | USER28 | USER29 | USER30 | USER31 | USER32
Range
NA
Default Value
WR10
Syntax Example
:SENS1:CORR:COLL:WAV:KIT WR12
:SENS1:CORR:COLL:WAV:KIT?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LABel <string>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LABel?
Description
Sets the waveguide calibration kit label on the indicated channel. Outputs the waveguide calibration kit label on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<string> The input parameter is any combination of numbers and letters.
See definition of <string>.
Query Parameters
<char1> The output parameter can be any combination of numbers and letters.
Range
NA
Default Value
WR10
Syntax Example
:SENS1:CORR:COLL:WAV:LAB ’wave1’
:SENS1:CORR:COLL:WAV:LAB?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:L0 <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:L0?
Description
Sets the waveguide calibration kit L0 (L zero) load inductance on the indicated channel. Outputs the waveguide calibration kit load inductance on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Henrys.
Cmd Parameters
<NR3> The output parameter is in Henrys.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:LOAD:L0 7.5E1
:SENS1:CORR:COLL:WAV:LOAD:L0?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:OFFSet <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:OFFSet?
Description
Sets the waveguide calibration kit load offset on the indicated channel. Outputs the waveguide calibration kit load offset on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Meters.
Query Parameters
<NR3> The output parameter is in Meters.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:LOAD:OFFS 2.5E1
:SENS1:CORR:COLL:WAV:LOAD:OFFS?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:R <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:R?
Description
Sets the waveguide calibration kit load resistance on the indicated channel. Outputs the waveguide calibration kit load resistance on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Ohms.
Query Parameters
<NR3> The output parameter is in Ohms.
Range
MPND
Default Value
5.00000000000E+001
Syntax Example
:SENS1:CORR:COLL:WAV:LOAD:R 7.5E1
:SENS1:CORR:COLL:WAV:LOAD:R?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C0 <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C0?
Description
Sets the waveguide calibration kit open capacitance C0 (C zero) value on the indicated channel. The C0 coefficient is measured in Farads. Outputs the waveguide calibration kit open capacitance C0 value on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Farads.
Query Parameters
<NR3> The output parameter is in Farads.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:OPEN:C0 3.0E-12
:SENS1:CORR:COLL:WAV:OPEN:C0?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C1 <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C1?
Description
Sets the waveguide calibration kit open capacitance C1 (C one) term on the indicated channel. The C1 coefficient is measured in Farads/Hertz. Outputs the waveguide calibration kit open capacitance1 term on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Farads/Hertz.
Query Parameters
<NR3> The output parameter is in Farads/Hertz.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:OPEN:C1 3.0E-12
:SENS1:CORR:COLL:WAV:OPEN:C1?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C2 <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C2?
Description
Sets the waveguide calibration kit open capacitance C2 term on the indicated channel. The C2 coefficient is measured in Farads/Hertz^2. Outputs the waveguide calibration kit open capacitance C2 term on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Farads/Hertz^2.
Query Parameters
<NR3> The output parameter is in Farads/Hertz^2.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:OPEN:C2 3.0E-12
:SENS1:CORR:COLL:WAV:OPEN:C2?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C3 <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C3?
Description
Sets the waveguide calibration kit open capacitance C3 term on the indicated channel. The C3 coefficient is measured in Farads/Hertz^3. Outputs the waveguide calibration kit open capacitance C3 term on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Farads/Hertz^3.
Query Parameters
<NR3> The output parameter is in Farads/Hertz^3.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:OPEN:C3 3.0E-12
:SENS1:CORR:COLL:WAV:OPEN:C3?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:OFFSet <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:OFFSet?
Description
Sets the waveguide calibration kit open offset on the indicated channel. Outputs the waveguide calibration kit open offset on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Meters.
Query Parameters
<NR3> The output parameter is in Meters.
Range
MPND
Default Value
0.00000000000E+000
Syntax Example
:SENS1:CORR:COLL:WAV:OPEN:OFFS 1.2E-4
:SENS1:CORR:COLL:WAV:OPEN:OFFS?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SERial <string>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SERial?
Description
Sets the waveguide calibration kit serial number on the indicated channel. Outputs the waveguide calibration kit serial number on the indicated channel.
Cmd Parameters
<string> The input parameter is any combination of numbers and letters. See definition of <string>.
Query Parameters
<char1> The output parameter can be any combination of numbers and letters.
Range
NA
Default Value
NA
Syntax Example
:SENS1:CORR:COLL:WAV:SER ’12012008’
:SENS1:CORR:COLL:WAV:SER?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT1:OFFSet <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT1:OFFSet?
Description
Sets the waveguide calibration kit short1 offset on the indicated channel. Outputs the waveguide calibration kit short1 offset on the indicated channel.
Cmd Parameters
<NRf> The input parameter is in Meters.
Query Parameters
<NR3> The output parameter is in Meters.
Range
MPND
Default Value
See Calibration Component Parameters.
Syntax Example
:SENS1:CORR:COLL:WAV:SHORT1:OFFS 1.2E-4
:SENS1:CORR:COLL:WAV:SHORT1:OFFS?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT2:OFFSet <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT2:OFFSet?
Description
Sets the waveguide calibration kit short2 offset on the indicated channel. Outputs the waveguide calibration kit label short2 offset on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Meters.
Query Parameters
<NR3> The output parameter is in Meters.
Range
MPND
Default Value
See Calibration Component Parameters.
Syntax Example
:SENS1:CORR:COLL:WAV:SHORT2:OFFS 5.0E-9
:SENS1:CORR:COLL:WAV:SHORT2:OFFS?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT3:OFFSet <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT3:OFFSet?
Description
Sets the waveguide calibration kit short3 offset length on the indicated channel. Outputs the waveguide calibration kit short3 offset length on the indicated channel. See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Meters.
Query Parameters
<NR3> The output parameter is in Meters.
Range
MPND
Default Value
See Calibration Component Parameters.
Syntax Example
:SENS1:CORR:COLL:WAV:SHORT3:OFFS 5.0E9
:SENS1:CORR:COLL:WAV:SHORT3:OFFS?
 
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SLOAD:MINF <NRf>
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SLOAD:MINF?
Description
Sets the waveguide calibration kit sliding load minimum frequency on the indicated channel. Outputs the waveguide calibration kit sliding load minimum frequency on the indicated channel.See Calibration Component Parameters for a complete listing of calibration components, connectors, and their Command Parameters.
Cmd Parameters
<NRf> The input parameter is in Hertz.
Query Parameters
<NR3> The output parameter is in Hertz.
Range
MPND
Default Value
2.00000000000E+009
Syntax Example
:SENS1:CORR:COLL:WAV:SLOAD:MINF 10.0E7
:SENS1:CORR:COLL:WAV:SLOAD:MINF?