:CALCulate{1-16}:PARameter{1-16}:MSTatistics <char>
:CALCulate{1-16}:PARameter{1-16}:MSTatistics?
Description
Sets the marker statistics display on and off for the indicated channel and trace.
Markers do not need to be turned on to display the statistics data. If the statistics are on, the statistics are determined for the entire sweep range. The three values displayed are Mean (Mean), Standard Deviation (Std Dev), and Peak-to-Peak (P-P), each measured in dB. Markers do not need to be displayed to output the statistics. If the marker statistics are displayed, a label of Stat Range Entire Sweep (Statistics Range – Entire Sweep) appears above the statistic values.
Returns the marker statistics display on/off state for the indicated channel and trace.
Cmd Parameters
<char> 1 | 0 | ON | OFF
Query Parameters
<char> 1 | 0
Range
NA
Default Value
0
Syntax Example
:CALC1:PAR1:MST ON
:CALC1:PAR1:MST?
 
:CALCulate{1-16}:PARameter{1-16}:MSTatistics:DATA?
Description
Query only.
Returns the three marker statistics of the upper display for the indicated channel and trace.
The statistics are determined for the entire sweep range. The three values output are Mean (Mean), Standard Deviation (Std Dev), and Peak-to-Peak (P-P), each measured in dB. The values are measured for the entire sweep range for the indicated trace. Markers do not need to be on to output (or display) the statistics.
Cmd Parameters
NA
Query Parameters
<NR3>, <NR3>, <NR3> Outputs marker on-screen statistics in units of dB.
Range
NA
Default Value
NA
Syntax Example
:CALC1:PAR1:MST:DATA?
:CALCulate{1-16}:PARameter{1-16}:MSTatistics:DATA2?
Description
Query only.
Returns the marker statistics of the lower display on the given trace of the indicated channel.
A dual display trace must be set up before sending the query.
The statistics are determined for the entire sweep range. The three values output are Mean (Mean), Standard Deviation (Std Dev), and Peak-to-Peak (P-P), each measured in dB. The values are measured for the entire sweep range for the indicated trace.
Markers do not need to be on to output (or display) the statistics.
Cmd Parameters
NA
Query Parameters
<NR3>, <NR3>, <NR3> Outputs marker on-screen statistics.
Range
NA
Default Value
NA
Syntax Example
:CALC1:PAR1:MST:DATA2?