Site Master™ S331P : Overview : User Interface Overview
 
User Interface Overview
The S331P Graphical User Interface consists of a trace window, function menu keys, shortcut tool bars, and a virtual keypad on the right.
S331P User Interface
Virtual Keypad
Table: Site Master Keypad Functions (1 of 3) provides a description of user keys on the virtual keypad of the S331P interface screen. The numeric keys are used to access functions listed in the table and also to enter numerical digits when a parameter edit box is open.
Site Master Keypad Functions (1 of 3)
Key
Description
Opens the Menu Shortcut window, where you can switch between Cable-Antenna Analyzer Advanced and Classic Modes. Refer to Menu Shortcut Window.
Applies a user-specified setting or executes the currently selected action.
Moves or scrolls up a list.
Moves or scrolls down a list.
In File Management, closes the currently selected folder (that is, moves up one folder level). When a marker is selected (red vertical line), moves the marker left.
In File Management, opens the currently selected folder (that is, moves down one folder level). When a marker is selected (red vertical line), moves the marker right.
Cancels a parameter value being entered or closes the current dialog box or screen without applying changes.
Accesses the Help feature, where you can view system information and a list of Frequently Asked Questions (FAQ), or open this manual in a browser page. Refer to Help.
Allows the user to save, recall, copy, and delete files in local or removable disk. Refer to File Menu.
Displays the Sweep Setup menu. Refer to Sweep Menu.
Captures an image of the current display and saves a PNG file to the default location. Files are named based on the measurement type and current date and time. Refer to Screen Shot Capture for additional information.
Displays the Trace menu. Trace operations include Copy Trace to Memory, Display Trace only, Display Memory only, Display Trace and Memory. Trace math functions include Trace – Memory, Trace + Memory, (Trace + Memory) / 2, or none. Refer to Trace for detailed instructions.
Displays the Limit menu to set user defined limits. Limit Alarms and Pass/Fail messages may be activated to indicate when a limit has been exceeded by the active measurement. Refer to Cable and Antenna Measurements for Cable & Antenna mode. Refer to Limit Menu for the Classic mode Limit menu.
Opens the Save dialog box for quick saving of the current measurement, setup, or screen display. Files can be saved to your tablet or PC local disk or to a removable storage drive. Refer to Save File.
Opens the System menu and provides access to System Information, System Setups, and Diagnostic tools. Refer to System Operations for additional information.
Opens the Preset/Reset submenus for resetting the Site Master back to default settings, deleting custom files and user files. Refer to Preset Menu.
Auto scales the Amplitude axis. Refer to Amplitude Menu.
Toggles the sweep setup of the active measurement between Run and Hold. Hold retains the last measured value on the display until the unit is placed back into Run mode. Refer to Sweep Menu.
Exits the Site Master application.