:CALCulate{1-16}[:SELected]:SMITh Subsystem
The :CALCulate{1-16}[:SELected]:SMITh subsystem commands are used to configure Smith chart-related displays.
Trace Subsystems
Related trace subsystems are:
:CALCulate{1-16}[:SELected]:SMITh:IMPedance <NRf>
:CALCulate{1-16}[:SELected]:SMITh:IMPedance?
Description
The display type must be Smith chart.
Sets the impedance to use for Smith chart-related displays on the active trace of the indicated channel.
Returns the impedance to use for Smith chart-related displays on the active trace of the indicated channel.
Cmd Parameters
<NRf> The input parameter is in Ohms.
Query Parameters
<NR3> The output parameter is in Ohms.
Range
MPNF
Default Value
5.000000E+001
Syntax Example
:CALC1:SMIT:IMP 7.5E1
:CALC1:SMIT:IMP?
:CALCulate{1-16}[:SELected]:SMITh:WRAP <NRf>
:CALCulate{1-16}[:SELected]:SMITh:WRAP?
Description
The display type must be Smith chart.
Sets the wrap offset to use for a Smith chart display on the active trace of the indicated channel.
Returns the wrap offset to use for a Smith chart display on the active trace of the indicated channel.
Cmd Parameters
<NRf> The input parameter is a unitless number.
Query Parameters
<NR3> The output parameter is a unitless number.
Range
-3.6E2 to 3.6E2
Default Value
0.000000E+000
Syntax Example
:CALC1:SMIT:WRAP 2.10E1
:CALC1:SMIT:WRAP?